310 z SIMPL+
®
Language Reference Guide - DOC. 5797G
Compiler Error 1307
declaration error: Variables must be declared before array
declarations: '<identifier>'
I/O declarations must be declared in a specific order. All arrays of an I/O declaration
type (i.e.: DIGITAL_INPUT) must be declared after any variables of the same type.
The following are examples of this error:
DIGITAL_INPUT di1, di2; // ok
DIGITAL_INPUT di3; // ok
ANALOG_INPUT ai1 // ok
DIGITAL_OUTPUT do1; // ok
ANALOG_INPUT aiArr1[10]; // ok
DIGITAL_INPUT di4; // ok – no DIGITAL_INPUT array exists
yet
DIGITAL_INPUT diArr1[10]; // ok
DIGITAL_OUTPUT do2; // ok
ANALOG_INPUT aiArr2[20]; // ok – multiple arrays are allowed
DIGITAL_INPUT di5; // error – cannot define after diArr1
ANALOG_INPUT ai2; // error – cannot define after aiArr2