Language Reference Guide - DOC. 5797G
Example:
(Refer to "File Functions Overview"on page 116)
SIGNED_INTEGER nFileHandle, nTotalBytesRead;
STRUCTURE PhoneBookEntry
{
STRING Name[50];
STRING Address[100];
STRING PhoneNumber[20];
};
PhoneBookEntry OneEntry;
StartFileOperations();
nFileHandle = FileOpen ( “MyFile.txt”, _O_RDONLY );
if (nFileHandle >= 0)
{
ReadStructure( nFileHandle, PhoneBookEntry,
nTotalBytesRead );
if( nTotalBytesRead < 0 )
PRINT ( “Error reading structure. Error code = %d\n”,
nTotalBytesRead );
else
PRINT ( “Read structure from file correctly. Total
bytes read = %d\n”, nTotalBytesRead );
}
EndFileOperations();
Version:
SIMPL+ Version 3.00.07 or higher (Pro 2 only)