6.4.2 Slip Paper Collector connecon
6.4 Slip Paper Collector
6.4.1 Slip Paper Collector structure
6.4.3 Slip Paper Collector unit maintenance
6.5.3 Using the Straight In-line Bridge
6.5.4 Straight In-line Bridge maintenance
6.5 Straight In-line Bridge
6.5.2 Straight In-line Bridge connecon
6.5.1 Straight In-line Bridge structure
Air outlet
(nozzles)
Slip paper rollers
Power control cable connecon
Fans
1
6
2
3
4
5
1
6
2
3
4
5
Chapter 6: Oponal Devices
The Slip Paper Collector is an oponal device used to separate slip papers on the H model CTP device, remove
and organize slip papers effecvely, increase the number of single delivery, and reduce the manual intervenon on
slip paper handlings.
Aach the Slip Paper Collector unit under the slip paper outlet path according to the screw holes posion
provided, then connect the power control cable to the port shown below,
a) Regularly clean the air outlet nozzles
b) Regularly check the condions & cleanliness of the slip paper rollers
c) Regularly check the transmission gears lubricants& condions
d) Regularly check the fans operaon
The Straight In-line Bridge is oponal peripheral, aaches to the host CTP device for transporng the CTP
exposed plate output to the processor unit, or it can be a temporary single plate stacker.
a) Note: when ordering the Straight In-line Bridge to be bundled with the
host CTP device, reserved BGP connector port will be replaced with cable
connecon port for Straight In-line Bridge connector.
b) USB port connecon for host CTP device TP26 / TP36 / TP46 / TP60
models can be located on the same connecvity panel as shown in below;
c) For TP72CTP device, the Straight In-line Bridge connector is located
lower le underneath where the bridge installed.
a) Plate Stoppers is closed (flat): bridge is in full working mode. Plate will be transported through the bridge into
the processor unit;
b) Plate Stoppers is opened (flip up): convert bridge become atemporary single plate stacker.
a) Regularly clean the conveyor belt, conveying the upper plane
b) Regularly check bridge level(height) and posion against CTP & processor
c) Regularly check the working mode is valid.
Conveyor belts
Plate stoppers
Bridge connecon cable port
TP72cable connecon port
Bridge installaon bracket
Bridge support arms
3332
SIMPLE AND DIRECT 丨 STEADY 丨 MAJOR
SIMPLE AND DIRECT 丨 STEADY 丨 MAJOR