Chapter 8: Abnormal Problems Analysis and Handling
使
Attention!
Table 8-1LaBoo error information and handling suggestions
8.1 Error message and handling suggestions
Before proceeds for HDI device inspection and hardware handling, please wait for at least 5 minutes
after power turned off to avoid electrical shock.
Device inspection, diagnostic, handling and replacement of parts components should be only
conducted by well trained and qualified technical personnel appointed by CRON.
Technical personnel involve in diagnostic and troubleshooting works should remove all metal items
from body before carry out the works. Use the insulating tools to avoid electrical shock and
precautions of injury.
No.
ErrorMessage .Handlingsuggestion
1
Imagesizeissmallerthanplatesize,joboutputisstopped.
Click“allowlargeplatewithsmallerimagesizeoutput”
undersystemparameterssettingmenu.
2
Jobsizeisbiggerthanplatesize,cannotbeoutput,
pleaseadjustparameters.
Checkjobsizeandresetparameters.
3
Originalfileisdeleted,cannotbemoved. Thisfileisdeleted,tryopenanotherfile.
4
Erroronreaddeviceparameters. Pleaseretryagainorcontactengineer.
5
Dongleisabnormal!Pleasere-plugdongle
.Checkifdongleisproperlypluggedorcontactengineer.
6
Templatenamecannotcontain:“'":|?*\\/<>”.
Chooseotherletters.
7
Invalidenter!
Chooseotherletters.
8
CannotopenTifffile PleaseconfirmTIFFfileformat.
9
Setupisnotcomplete!
Someofparametersarenotcorrect.
10
PleasestopHotfolderfirst. Tickoffinfrontoftemplatename.
11
Hotfolderisalreadyinuse! Changeanotherhotfolder.
12
Templatealreadyexists!
Changetoanothertemplatename.
13
Incorrectresolution,cannotoutput.
Tiffresolutionisnotsameascurrenttemplate.
14
Imagefileisdamaged. Checkifimagefileformatiscorrect.
15
Thereisnopassedusagerecord,updatefailed!
Contactengineer.
16
Parametersarenotforthismachine,cannotcompleteparameterread,
thisisformachine:***
Checkmachineserial.
17
Plateformatisoverlimit.Deleteunusedplateformatandtryagain. Plateformatmax.is32.
18
Parametersarenotcorrect.Devicecannotbeoperational.
Checkdeviceparametersorcontactengineer.
19 Deviceisnotpoweronorhardwarecannotsupportsoftware. Pleaseupdatesoftwareorcontactengineer.
20
Parametersarenotcorrect.Devicecannotbeoperational.
Checkdeviceparametersorcontactengineer.
21 Deviceisnotpoweronorhardwarecannotsupportsoftware. Pleaseupdatesoftwareorcontactengineer.
22
Pleasecleanlens
Doresolutionadjustmentandfollowinstructionstocleanlens.
23
Cannotfinddongle
.Checkdongle.
24
Commandexecutefailed!
Donotsendthiscommandundercurrentstatus
25
Turnoffmachineanduseair-contochange
temperatureorContactengineer
Laserboxtemperatureabnormal,cannotoutput
currentis**degreeshallbe15-35degree.
26
Devicetemperatureabnormal,cannotoutput!
Currentis**degree,shallbe10-35degree.
Turnoffmachineanduseair-contochangetemperature
27
Resetclockfailed!
Contactengineer
28
Outputreacheslimit!Contactengineer.
Contactdealerimmediately
29
Softwareauthorizedlimitislessthan500timesPleasecontactdealer!
Contactdealerimmediately
30
Softwareauthorizedoutputisuptodate,outputistopped.
Pleaecontactdealer!
Contactdealerimmediately
31
Laserpowerlockerrorchannel***.
Enterlaseradjustprogramandtestlaserpower
32
Laserpowerrangeisnotcorrect,suggesttochange**to**.
Followthemessagetochangeparameters
33
Readdeviceparametersfailedmaybeversionisnotcorrect
Readdeviceparametersagainorcontactengineer!
34
Resetwithoutengineer.
Contactengineer.
35
Pleaseadjustthefocus.
Checkandstart.
36
NOdongle!
Ensuredongleisplugged-inanddriveiscorrectlyinstalled.
37
Usepreviewunderstand-bystatus
Cancel“continuousoutput"andtryaga
38
Commandisnotallowedundercurrentstatus.
Finishcurrentstatusandtryagain.
39
Softwarelimitisnearlyup-to-date.
Contactdealerimmediately.
40
Laserpowertestparameterssettingisnotcorrect,suggest
todecreaselevelsorincreasevalueofeachlevel
Reducelevelsorcontactengineer.
41
Devicewillchangeformat,pleaseconfirmplates
onloadingtrayareremoved!
Ensureplatesizeiscorrectorstackisok.
42
Cannotlocatesystemrequiredmemory
RestartcomputerorreinstallOS
43
USBcommunicationfailed.Makesuretoinstallcorrect
USBdriveorcontactengineer
CheckifUSBdriveiscorrect.CheckisUSBportis
normalorchangeanothercomputer
44
CannotconnecttoAutoloader
Ensureautoloaderispoweredonandcablesareconnected
45
Drumspeedisnotstable
CheckCTPpowersupply,emergencystop,
topcoverprotectorContactengineer
46
Drumcannotreachrequiredspeed!
CheckCTPpowersupply,emergencystop,
topcoverprotectorContactengineer
47
Drumstartabnormal
CheckCTPpowersupplyorContactengineer
48
Tailclampadjustfailed.
PleasecleanairslotondrumorContactengineer
49
Tailclamppositionisoverlimit,pleasecheck.
PleasecleanairslotondrumorContactengineer
50
Platesizeisoverlimit(drumcannotbebalanced!).
PleasecleanbalanceblocksensororContactengineer
51
Vacuumpressureisnotcorrect.
Checkairpumpfilter
52
Tailclampfailed,pleaseturnoffandcheck.
PleasecleanairslotondrumorContactengineer
53
Mainboardcontrolprocessstartfailed.
RestartCTPandPCorContactengineer
54
Autoloadercontrolprocessstartfailed.
RestartautoloaderorContactengineer
55
Plateloadinglasttimeabnormal!
Checkplatestack
56
Lasercannotbestarted!
OpenlaseradjustprogramorContactengineer
57
Cannotconnecttoautoloader.
Checkpowersupplyandcableconnection
60
Drumcannotstop!
Contactengineer
61
Alreadyplateondrum.
Checkifplateondrumordo#105test
commandorcontactengineer
62
Cannotconnecttodevice!Makesuredeviceis
poweronandUSBcableisconnectedorcontactengineer!
Checkpowersupply,USBconnectionandUSBdrive.
63
Cannotreadparameterfileinformation!
Checkifparameterfileiscorrect
64
DeviceIDvalidatefailed.
ReaddeviceIDagainorcontactengineer
65
Temperaturecompensationisnotcompleted(overtime)!
Checkplatformfocuscompensation
movementorcontactengineer.
66
Maincontrolboarddataflowisabnormal.
RestartPCorContactengineer
67
Whenstartrecordprocess,datainmain
controlboardmemoryisnotready!
RestartPCorContactengineer
68
Cannotstartrecordprocess,platformpositionlimitsignalisnotcorrect.
CheckplatformpositionlimitsensororContactengineer
69
Cannotfindthiserrorcodeinformation.
Contactengineer
70
Imageformatisunknown.
Checkifdongleispluggedin
71
Filesize##*##isovertemplatesetting,cannotopenthisfile.
Setupanothertemplateoradjustcurrentone
72
Resolutionisnotsame,astemplatesetting,cannotopenthisfile!
Setupanothertemplateoradjustcurrentone
73
Parameterisoverlimit!
CheckparameterorContactengineer
74
Softwareversionistooold,cannotread
parameter!Pleaseupdatesoftware.
Updatecurrentsoftware
No.
ErrorMessage .Handlingsuggestion
4544
SIMPLE AND DIRECT STEADY MAJOR
SIMPLE AND DIRECT STEADY MAJOR