3.11 Troubleshooting
3.11.1 Factory Default.
Apply power to IMC-1000MS and allow 25-30 seconds to fully boot. Using a pencil or ball-point pen, press the 'DEFAULT' recessed push-
button switch (located on the face plate) and hold for 10 seconds or more then release. DO NOT POWER OFF; Allow the unit to again fully
reboot (about 25 seconds). The factory default TCP/IP settings are:
IP=10.1.1.1
netmask=255.255.255.0
GW=10.1.1.254
The username and password are both reset to 'admin'.
Additionally, any VLAN, 1Q or bandwidth control will be disabled. All ports will be enabled, UTP ports set for auto-negotiation.