© CUB CAMPERS • C16 OWNER’S MANUAL • REVISION 1 - 6/02/2023 PAGE 9 of 59
Smoke Alarm
Click for QUELL Smoke Alarm User Manual
The C16 is fitted with a Quell Smoke Alarm with Hush function. Refer to Smoke Alarm user
manual for information about operation and maintenance.
WARNING: TEST YOUR SMOKE ALARM OPERATION AFTER CARAVAN OR MOBILE HOME
VEHICLE HAS BEEN IN STORAGE, BEFORE EACH TRIP AND AT LEAST ONCE A WEEK DURING USE
Testing
Test the unit to ensure proper operation, by pressing the Test/Hush button for at least 5
seconds (or until the unit sounds). This will sound the alarm if the electronic circuitry, horn,
and battery are working.
CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an arms-length away
from the unit when testing.
If no alarm sounds, the unit has a defective battery or other failure. DO NOT use an open flame
to test your alarm, you could damage the alarm or ignite combustible materials and start a
fire. Erratic or faint sound coming from your alarm may indicate a defective alarm.
Low Battery
This alarm has a low battery monitor which will cause the alarm to “chirp” approximately
every 40-50 seconds for a minimum of 30 days when the battery gets low. Use only the
following 9-volt batteries for replacement:
Alkaline Type
• Energizer 522
• Duracell MN1604 or MX1604
• Gold Peak 1604A
• Panasonic 6AM6, 6AM-6, 6AM-6PI, 6AM6X or 6LR61(GA)
Lithium Type
• Ultralife U9VL-J
Smoke Sensing Chamber Operation
This alarm will “chirp” if it detects a problem with the smoke sensing chamber. This chirp will
occur approximately 20 seconds after the flash of the red LED indicator light.
Clean the alarm. If the alarm is still chirping, replace the alarm.
LED indicators:
This alarm is equipped with a red LED indicator, with three modes of operation.
Red LED - Flashing every 40–50 seconds: Indicates that the smoke alarm is operating properly.
Red LED - Flashing: When the Test/Hush button is pressed, or when the smoke alarm senses
particles of combustion and goes into alarm (constant pulsating sound), the red LED will flash
once per second. The flashing LED and pulsating alarm will continue until the air is cleared.
Red LED - Alarm silencer (Hush
TM
mode) indication: The red LED will flash every 11 seconds,
indicating the smoke alarm is in the alarm silencer (Hush
TM
) mode.