EasyManua.ls Logo

CUH SDVC31 Series - Chapter Ⅱ Features

CUH SDVC31 Series
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CUH CUH CUH CUH CUH CUH CUH
CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH
CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH
CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH
CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH
CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH
CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH
CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH
CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH CUH
4
Chapter Features
SDVC31 Series
Variable Frequency Digital Controller for Vibratory Feeder
SDVC31SMSEN_4.012023-08
The controller is specially designed for controlling vibratory feeder in the
automation systems. Combined with the latest electronic technology and
elaborate design, the controller provides the following convenient and
practical features:
Frequency Adjusting: Output Frequency ranges from 40.0Hz to 400.0Hz.
Voltage Adjusting: Output Voltage ranges from 0V to 250V.
Automatic Voltage Stabilizing: The controller can eliminate feeding speed
variation caused by mains voltage fluctuation.
Soft Startup: In order to avoid sudden shock to the work pieces, the controller
can gently increase output voltage from 0 to the pre-set value when startup.
Intelligent Photoelectric Sensing: Our adaptive Intelligent Photoelectric
Sensor can help to stall the controller when work-pieces are full or work-piece
is empty and to fulfill the functions of Soft Startup Time Setting, On Delay, Off
Delay, and Logical Relation Adjusting.
Switch Sensor: Adaptive switch sensor or PLC can be connected to turn on/off
the controller.
Acceleration: Due to this function, maximum output voltage value of the
controller can be increased up to 150% of the input voltage value.
Remote Speed Control: Output Voltage of the controller can be controlled by
an external potentiometer, a PLC, or a 1~5V/4~20mA DC signal.
Controlling Output: The Controlling Output signal outgoing from the
transistor can coordinate a solenoid or other external devices with the
controller.
Keypad Locking: Press the ON/OFF button and hold for 2 seconds to lock all
buttons for fear of false operation. When in the locked state, the operation
button does not respond and this indicator flashes.
Maximum Output Restriction: Maximum Output Voltage value can be preset
to protect the equipment from damage caused by misuse.
Waveform Index Setting: Operators can weight efficiency and maximum
capacity by adjusting this parameter.
Default Settings Restoration: This function allows the user to restore all
default parameter settings and reset the controller.