Page 19 - Revision:EU-2020-10-13
RECOMMENDED STOCK HOLDING (CONSUMABLES)
Culligan technical manuals cover voltages of both 120v and 220v for all our markets. Please ensure
that you carefully read the information in this manual and for any parts specific to any market, refer
to your technical agreement or specific part listing.
Solenoid Valve (recommend
replacing Solenoid Cushion at same
2
Drip Tray No Logo
Drip Tray Grill
Overheat with Manual reset-97°C
Hot Tank 1.5 Litre 220-240V / 500W
Factory Set Point 85°C (185°F)
Hot Tank 1.5 Litre 120v/500W
Factory Set Point 85°C (185°F)
2
Replacement parts can be obtained from Culligan or an Authorized Culligan Dealer. See
Parts Layouts, Drawings, and Lists for additional repair parts.
Sanitizing
Sanitization must be performed at least once a year to eliminate any potential microbiological
contaminates. See Sanitizing Instructions in the Pre-Installation section of this manual.
Hot Tank Service
Hot Tanks (with controls) must be replaced at least every 3-5 years depending on usage. Descaling
Hot Tank may be required on a regular basis depending upon filtration and local water conditions.
See Hot Tank Descaling Instructions Section of this manual.
NOTE:
At the end of this product’s life, ensure that it is disposed of in an environmentally friendly manner