HOT WATER TROUBLESHOOTING INDEX
Hot Water is not Hot 85°C ± 5°C
The Hot Temperature set point is 85°C (185°F) and is controlled by a thermostat on the side of the
Hot Tank.
There is a resettable overload or high limit safety above the thermostat on the side of the Hot Tank
that will trip to prevent damage to the unit if the tank is dry heated (turned on without water in it).
The C100 Water Treatment System does NOT have Extra Hot capability and the maximum hot
temperature is 87°C (189°F).
It typically takes 10 minutes for the 500W to heat the 1.5 Litre of room temperature (ambient) water
to the 85°C (185°F) set point.
I = ON
Possible Reason
Solution
No power to Heater elements
Check that the Red Heater and Compressor switch is
on.
Turn Red Heater and Compressor Switch on.
Hot Tank Overheat Tripped
Overheat is a safety feature to
ensure the tank does not
overheat.
Overheat will “click” when pushed. The overload is automatically
reset when pressed.
Thermostat or over heat
“open” on Hot Tank
Turn Power off. Check OHM’s resistance across terminals on each
Thermostat and Overload separately.
Good components will indicate a closed circuit or zero OHM’s on
the meter.
Replace components as necessary.
Loose or improperly
connected wire(s) to the
heating element / Hot Tank.
Visually inspect wire leads gong to the Hot Tank; confirm proper
connections to the heating elements.
Hot Tank life is 3-5 years depending on usage, depending on
usage.
Heating Coil Not Working
Turn Power off; Drain Hot Tank; Use multi-meter to check Heater
element for approximately 26 OHM’s resistance.
Hot Tank must be empty if you are checking for continuity.
Replace Hot Tank as necessary.