COLD WATER TROUBLESHOOTING INDEX
Cold Water is not Cold (5° +/- 3°C)
Possible Reason
Solution
No power or refrigeration
elements
Check that the Red Heater and Compressor switch is
on.
Turn Red Heater and Compressor Switch on I = ON
Tank has run out of cold water.
Cold Tank capacity:
Tower: 4 litres (1 Gallon)
Counter Top: 2 Litters (1/2
Gallon)
Wait for Cold Tank to chill water to temperature prior to dispensing
more cold water.
A greater capacity of Culligan Water Systems is available.
Cold Water Thermostat
Check continuity of thermostat with multimeter. Replace
thermostat as required.
Refrigerant has run out
Run Compressor for at least ten minutes. If condenser is not warm
then refill the refrigerant.
Compressor problem If Compressor is not running, repair or replacement is needed.