16 Culligan® All Purpose Cooler
16 Cat. No. 01023621
Sanitize the Unit
1. Slowly turn ON the water supply. The incoming water will mix with the chlorine.
2. Press and hold the large dispense (A) button to start flushing water through the unit. (See page 12 for details
on the operation of the control buttons).
NOTE It may take several minutes before the cold tank is full and water flows from the dispensing head.
3. Stop when water with a chlorine smell starts to flow from the dispensing head.
4. Do not dispense any of the sanitizing solution through the hot tank.
5. Allow the sanitizer solution to stand in the unit for 20-30 minutes.
6. Activate and hold the large dispense (A) button. Flush 3 gallons through the unit and the cold tank.
7. Activate and hold the hot (both B and C) buttons. Flush 3 gallons through the hot tank.
Remove the Sanitizing Cartridge
1. Turn OFF the water supply. Activate the dispense button to relieve any pressure in the unit.
2. Unplug the power cord.
3. Remove the sanitizer cartridge and EZ head. Reconnect the inlet feed tubing to the unit.
4. Remove all bypass plugs from the heads or the empty housings on an AC 50 RO configuration.
Replace the Filter
NOTE Prepare all filters, RO cartridges, and the RO storage tank strictly in accordance with the instructions
included in the Appendix section of this manual.
1. On units using RO, reconnect a full RO storage tank that has been sanitized separately per the instructions
in the Appendixes.
2. Install new filters.
3. On units using RO, reconnect the carbon post filter.
4. Plug in the power cord.
CAUTION! The unit is now live. Take suitable safety precautions.
5. Replace batteries on external leak controller.
Sanitizing the All Purpose Cooler