SETTINGS 7
Settings
The mircoprocessor can be set in two distinct operation modes, Soft-Minder
®
meter or Timeclock. As shipped from
the factory, the control is set for 8" Timeclock operation.
CAPACITY AND SALT SETTINGS
As mentioned previously, the softener will regenerate once the amount of water equal to the treated water
volume set point has passed through the turbine for meter models or after a xed time interval for timeclock
models. Regeneration is either delayed until the selected regeneration time or immediate depending on how the
microprocessor is programmed. Before completing the programming, the following information must be determined:
1. Compensated Water Hardness.
If your water supply contains iron, compensate for it by the following procedure:
1. Multiply the iron by 0.1 and add the result to the hardness.
Example: (3 ppm of iron x 0.1) + 25 gpg of hardness = 25.3 gpg of total hardness
2. Choose the % capacity you want and refer to the table below for the appropriate multiplier.
Example: 67% capacity gives a multiplier of 1.5.
TABLE 3
% Capacity 50% 67% 75%
Multiplier 2 1.5 1.33
3. Multiply the result from Step 1 by the multiplier chosen in Step 2. This is the compensated hardness.
Example: 25.3 gpg total hardness x 1.5 = 38 gpg compensated hardness.
4. Use the effective hardness for sizing and to determine salt dosage and regeneration frequency.
5. The forced regeneration feature should be used for Soft-Minder meter operation to ensure the resin bed
does not become iron fouled due to lack of water ow. See "Programming the Option Settings" for the
forced regeneration feature.
2. Salt Dosage
From Table 4, select the salt dosage at which the softener will be operated.
Low Setting — Maximum salt efciency, more frequent regeneration, reduced overall softening capacity.
Medium Setting — Good combination of efciency and overall softening capacity.
High Setting Maximum softening capacity, less frequent regeneration, and reduced salt efciency.
Recommended whenever iron is present and for hardness levels above 30 Grains Per Gallon, or high volume
water usage.

Other manuals for Culligan MEDALLIST SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Culligan MEDALLIST SERIES and is the answer not in the manual?

Culligan MEDALLIST SERIES Specifications

General IconGeneral
TypeWater Softener
Flow RateUp to 12 gallons per minute
Resin TypeHigh-capacity resin
DimensionsVaries by model
WeightVaries by model
Tank MaterialFiberglass

Related product manuals