EasyManua.ls Logo

Curtis 1234E - Can Interface Menu

Curtis 1234E
157 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE Manual, os 30
24 NOVEMBER 2015
3 — PROGRAMMABLE PARAMETERS: CAN Interface Parameters
CAN INTERFACE MENU
ALLOWABLE
PARAMETER RANGE DESCRIPTION
CANopen Interlock On / Off When programmed On, CAN NMT State must = 5 (operational state)
CANopen_Interlock_Enable On / Off in order for the interlock to be set; see Monitor » CAN Status menu, page 85.
OptionBits3 [Bit 2]
0x306C 0x00
CAN Node ID 1 1 127 The Node ID for the primary microprocessor is determined by the state
CAN_Node_ID_1 1 127 of switches 5 and 6 at KSI turn on:
0x3140 0x00 Node_ID_1 is selected when Sw 6 = Off and Sw 5 = Off
Node_ID_2 is selected when Sw 6 = Off and Sw 5 = On
Node_ID_3 is selected when Sw 6 = On and Sw 5 = Off
Node_ID_4 is selected when Sw 6 = On and Sw 5 = On.
IftheselectedparameterhasaNodeIDofzero,theNode_ID_1parameter
isused.IftheNode_ID_1parameterisalsozero,adefaultIDof38isused.
CAN Node ID 2 1 127 See description of Node ID 1.
CAN_Node_ID_2 1 127
0x3141 0x00
CAN Node ID 3 1 127 See description of Node ID 1.
CAN_Node_ID_3 1 127
0x3146 0x00
CAN Node ID 4 1 127 See description of Node ID 1.
CAN_Node_ID_4 1 127
0x3147 0x00
Supervisor Node ID 1 127 Sets the Node ID for the supervisor microprocessor. The Node ID is the
Supervisor_Node_ID 1 127 rst7bitsofthe11-bitidentier(theCOBID).
0x3872 0x00
Baud Rate -3 – 4 Sets the CAN baud rate for the CANopen Slave system:
CAN_Baud_Rate -3 4 -3 = 20 kbit/s, -2 = 50 kbit/s, -1 = 100 kbit/s, 0 = 125 kbit/s,
0x3142 0x00 1 = 250 kbit/s, 2 = 500 kbit/s, 3 = 800 kbit/s, 4 = 1000 kbit/s.
Heartbeat Rate 16 200 ms Sets the rate at which the CAN heartbeat messages are sent from the
CANopen_Heart_Beat_Rate 4 50 CANopen Slave system.
0x1017 0x00
PDO Timeout Period 0 200 ms Sets the PDO timeout period for the CANopen Slave system. After the slave
CAN_PDO_Timeout_Period 0 50 controller has sent a PDO MISO, it will declare a PDO Timeout Fault if the
0x3149 0x00 master controller has not sent a reply PDO MOSI message within the set
time. Either PDO1 MOSI or PDO2 MOSI will reset the timer. Setting the PDO
Timeout Period = 0 will disable this fault check.