EasyManua.ls Logo

Curtis 1238SE - Controller Wiring: Basic Configuration

Curtis 1238SE
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 — INSTALLATION AND WIRING
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 Return to TOC
pg. 12
CONTROLLER WIRING: BASIC CONFIGURATION
A basic wiring diagram is shown in Figure 3. rottle and brake are shown in the diagram as 3-wire
potentiometers; other types of throttle and brake inputs are easily accommodated, and are discussed
in the following throttle wiring section.
e main contactor coil must be wired directly to the controller as shown in Figure 3 to meet EEC
safety requirements. e controller can be programmed to check for welded or missing contactor
faults and uses the main contactor coil driver output to remove power from the controller and motor
Figure 3
Basic wiring diagram, Curtis 1232E/SE, 34E/SE, 36E/SE, and 38E/SE motor controllers.
1232E/34E/36E/38E, 1232SE/34SE/36SE/38SE
CONTROLLER
SWITCH 16
J1-14
SWITCH 8
J1-33
REVERSE
SWITCH 7
J1-22
FORWARD
SWITCH 6
J1-12
SWITCH 5
J1-11
SWITCH 4
J1-10
SWITCH 3
J1-9
INTERLOCK
SWITCH 2 / ANALOG 2
J1-8
SWITCH 1 / ANALOG 1
J1-24
I/O GROUND
J1-7
THROTTLE POT HIGH
J1-15
THROTTLE POT WIPER
J1-16
POT2 HIGH
J1-27
POT2 WIPER
J1-17
POT LOW
J1-18
THROTTLE POT
BRAKE POT
AC
MOTOR
MAIN
J1-19
J1-3
J1-4
J1-5
J1-6
J1-13
PROP. DRIVER
DRIVER 4
DRIVER 3
DRIVER 2
DRIVER 1
KSI
COIL RETURN
MAIN
BRAKE
PROP. VALVE
J1-1
KSI
POSITION
FEEDBACK
**
J1-26
J1-31
J1-32
J1-7
J1-23
J1-35
J1-21
J1-34
CAN PORT
Connect jumper for 120
CAN bus termination
J1-25
J1-28
J1-29
J1-7
SERIAL PORT
(4-pin Molex)
4
3
1
2
CURTIS
MODEL 840
DISPLAY
8
6
5
EMERG. REV.
KEYSWITCH
B+
V
+5V
POSITION FEEDBACK B
CAN TERM L
CAN L
+12V
RX
I/O GROUND
U
W
POSITION FEEDBACK A
I/O GROUND
CAN TERM H
B-
CAN H
TX
PUMP
EMERGENCY
STOP
J1-20
DIGITAL DRIVER 6
J1-2
DIGITAL DRIVER 7
ANALOG OUT (0–10V) *
J1-30
MOTOR
TEMPERATURE
SENSOR
Note: KTY sensor shown.
The banded end must be
connected to I/O ground.
*
1232E and 1232SE do not include ANALOG OUT.
BATTERY
(24V–96V)
** quadrature encoder (ACIM motors)
sin/cos sensor (SPM motors)

Table of Contents