Curtis 1238SE - Installation and Wiring Guide; Mounting the Controller

Curtis 1238SE
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 — INSTALLATION AND WIRING
pg. 3
Return to TOC Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017
2 — INSTALLATION AND WIRING
MOUNTING THE CONTROLLER
e outline and mounting hole dimensions for the 1232E/SE controller are shown in Figure 2a, for the
1234E/SE controller in Figure 2b, and for the 1236E/SE and 1238E/SE controllers in Figure 2c. When
an Ampseal plug housing is mated with the 35-pin logic receptacle, these controllers meet the IP65
requirements for environmental protection against dust and water. Nevertheless, in order to prevent
external corrosion and leakage paths from developing, the mounting location should be carefully chosen
to keep the controller as clean and dry as possible.
Mount the controller to a at surface devoid of protrusions, ridges, or a curvature that can cause damage
or distortion to its heatsink (the base plate). Secure the controller using four 6 mm (1/4") diameter bolts
evenly torqued to the vehicles mounting surface. ese controller’s heatsink (bottom surface) have a typical
roughness grade of N8 (ISO 1302), with a atness tolerance of < 5 mm (0.13 per 25 mm). A thermal joint
compound is recommended to improve heat conduction from the controller heatsink to the vehicles
mounting surface. Typically, when properly mounted to a larger metal surface, additional heat-sinking or
fan-cooling is not necessary to meet the applications peak and continuous current ratings.
Figure 2a
Mounting dimensions,
Curtis 1232E and 1232SE
motor controllers.
B
-
U
71
169
180
5.5
7.0 thru, 4 plcs
140
129
5.5
V
W
B
+
8
Status LED
window
1232E
75
12
1232SE
M6 x 1.0, 5 plcs
Note: The SE has a thicker base.
Dimensions in millimeters.