5 — MONITOR MENU
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 Return to TOC
pg. 70
Monitor Menu: INPUTS
VARIABLE DISPLAY RANGE DESCRIPTION
Throttle Command
Throttle_Command
0x3216 0x00
–100.0 – 100.0%
–32767 – 32767
Throttle request to slew rate block.
Throttle Multiplier
Throttle_Multiplier
0x3213 0x00
–200.0 – 200.0%
–256 – 256
Multiplies or divides the throttle signal; useful in VCL throttle processing
(see Throttle Processing on page 104 and Figure 15 on page 105).
Mapped Throttle
Mapped_Throttle
0x3211 0x00
–100.0 – 100.0%
–32767 – 32767
Mapped throttle request.
(see Throttle Processing on page 104 and Figure 15 on page 105).
Throttle Pot
Throttle_Pot_Raw
0x3215 0x00
0.00 – 5.50 V
0 – 36044
Voltage at throttle pot wiper (pin 16).
Brake Command
Brake_Command
0x321A 0x00
0.0 – 100.0%
0 – 32767
Brake request to slew rate block.
(see Brake Processing on page 106 and Figure 15 on page 105)
Mapped Brake
Mapped_Brake
0x3212 0x00
0.0 – 100.0%
0 – 32767
Mapped brake request.
(see Brake Processing on page 106 and Figure 15 on page 105)
Pot2 Raw
Pot2_Raw
0x3217 0x00
0.00 – 5.50 V
0 – 36044
Voltage at pot2 wiper (pin 17).
PD Throttle
PD_Throttle
0x3210 0x00
0.00 – 100.00 %
0 – 32766
Proportional driver current request.
(see Interfacing the Proportional Current Driver and Figure 17 on page 109)
Steer Pot
Steer_Pot_Raw
0x38BB 0x00
0.00 – 6.25 V
0 – 32767
Voltage at steer pot wiper (pin 17) on Dual Drive traction slave.
(reference the Dual Drive supplement manual: 53097_E&SEDD_os31)
Steer Angle
Steer_Angle
0x38BA 0x00
–90 – 90
–90 – 90
Steer angle degrees calculated in Dual Drive traction master.
Interlock
|Interlock_State
|System_Flags1 [Bit 0]
0x322B 0x00
On / Off
On / Off
Interlock input on or off. The source of the interlock input is determined by
the Interlock Type parameter.
from Switch 3 (pin 9) if Interlock Type = 0
from VCL function if Interlock Type = 1
from KSI (pin 1) if Interlock Type = 2.
Emer Rev
|EMR_State
|System_Flags1 [Bit 1]
0x322B 0x00
On / Off
On / Off
Emergency reverse input on or off. The source of the emergency reverse
input is determined by the EMR Type parameter:
from Switch 1 (pin 24) if EMR Type = 0, or 2.
from VCL function if EMR Type = 1.
Analog 1
Analog1_Input
0x3204 0x00
0.00 – 10.00 V
0 – 1023
Voltage at analog 1 (pin 24).
Analog 2
Analog2_Input
0x3205 0x00
0.00 – 10.00 V
0 – 1023
Voltage at analog 2 (pin 8).
Switch 1
|Sw_1
|Switches [Bit 0]
0x3226 0x00
On / Off
On / Off
Switch 1 on or off (pin 24).
Switch 2
|Sw_2
|Switches [Bit 1]
0x3226 0x00
On / Off
On / Off
Switch 2 on or off (pin 8).