EasyManua.ls Logo

DAC GDC31 - Typical Interconnect Diagram

DAC GDC31
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Equipment Installation Manual,
GDC31 Roll Steering Converter
1049-2510-01 G.doc
1049-2510-01
Rev G Page 33 of 47
Figure 1 Typical Interconnect
14V OR 28 VDC BUS
GPS
TX OUT
SHIELD
2A
A+
3
16
GDC31
14
J1
1
<-RS232
SUPER FLAG OUT
25
10
8
6
4
7
HDG
1
5
3
2
GPS
11
12
EXCITATION
HDG ERROR IN
GROUND
AUTOPILOT
HDG ERROR FROM HSI / CDI
POWER COMMON
RX IN
SERIAL COMMON
BAUD SELECT 0
RSS OUTPUT
RSS COMMON
REF1
SWITCH / ANNUNCIATOR
P10280 (28V OR 14V)
REF2 6
AP OFFSET
SIGNAL REFERENCE
EXCITATION
9
21
22
BAUD SELECT 1
GAIN SELECT 0
SUPER FLAG IN
19
18
15
5
GAIN SELECT 1 10
TYPE SELECT 23
PHASE SELECT 13
PROGRAM PIN COMMON 11
1
2
3
4
PROGRAM PINS
GPS INTERFACE
AUTOPILOT INTERFACE 5
6
7
1
SEE TABLE 5
SEE TABLES 1 AND 2
2
SEE TABLE 4
3
SEE TABLE 3
4
FOR EXCITATION VOLTAGES GREATER THAN 15 VOLTS PEAK
5
6
FOR USE WITH AUTOPILOTS THAT USE A SIGNAL REFERENCE
7
SEE TABLES 1 AND 2
FOR EXCITATION VOLTAGES LESS THAN 15 VOLTS PEAK
SEE TABLES 1 AND 2
THAT IS A VOLTAGE ABOVE AIRFRAME COMON, TYPICALLY 5VDC
EXCITATION (15 Vpk to 42 Vpk)
EXCITATION (LESS THAN 15 Vpk)
8
ISOLATION COUPLER IS USED TO TRANSFORMER ISOLATE THE
GDC31 REFERENCE AND / OR OUTPUT FOR INSTALLATIONS WHERE
THESE SIGNALS ARE NOT REFERENCED TO AIRFRAME GROUND.
1049-4801-01
4
13
COUPLER
ISOLATION
12 14
11
2
9
6
10
5
13
2:1
2:1
2:1
2:1
LIGHTING VOLTAGE
24
12
GPS LAMP A
GPS LAMP B

Table of Contents