Wire zone
Tap corresponding positions to set area type, NO/NC, alarm status, enter delay and exit
delay.
Table 4-5 Parameter description
The number cannot be modified.
Select NO (normally open) or NC (normally closed) according to detector type.
It shall be the same as detector type.
Select corresponding type according to detector type, including IR, gas, smoke,
urgency btn, door, burglar alarm, perimeter and doorbell.
Instant Alarm: After armed, if an alarm is triggered, the device produces
siren at once and enters alarm status.
Delay Alarm: After armed, if an alarm is triggered, the device enters alarm
status after a specified time, during which you can disarm and cancel the
alarm.
Bypass: Alarm will not be triggered in the area. After disarmed, this area
will restore to normal working status.
Remove: The area is invalid during arm/disarm.
24 Hour: Alarm will be triggered all the time in the area regardless of arm
or disarm.
A zone in Remove status cannot be bypassed.
After entering delay, when armed area triggers an alarm,
entering armed area from non-armed area within the delay
time period will not lead to linkage alarm. Linkage alarm
will be produced if delay time comes to an end and it is
not disarmed.
Delay is only valid
to the areas of
Delay Alarm.