Users Manual
150
Local interface
Configure the settings for the local alarms.
Table 5-26 Local alarm settings
Parameter
Description
Alarm-in Port Select the channel number.
Alarm Name Enter the customized alarm name.
Enable Enable or disable the local alarm function.
Device Type In the
Device
Type
list, select
NO
or select
NC
as the voltage output type.
Schedule
Click
Setting
to display setting interface.
Define a period during which the motion detection is active. For details, see
"Setting Motion Detection Period" section in "5.10.4.1 Configuring Motion
Detection Settings."
Anti-Dither Configure the time period from end of event detection to the stop of alarm.
Alarm-out Port
Click
Setting
to display setting interface.
Local Alarm: Enable alarm activation through the alarm devices
connected to the selected output port.
Extension Alarm: Enable alarm activation through the connected alarm
box.
Wireless Siren: Enable alarm activation through devices connected by
USB gateway or camera gateway.
Post-Alarm
Set a length of time for the Device to delay turning off alarm after the
external alarm is cancelled. The value ranges from 0 seconds to 300 seconds,
and the default value is 10 seconds.
Show Message
Select the
Show Message
check box to enable a pop-up message in your
local host PC.