Table 5-46 Connection parameters
Parameter
Description
Max Connection
The allowable maximum clients accessing the Device at the same time,
such as WEB, Platform, and Mobile Phone.
Select a value between 1 and 128. The default value setting is 128.
TCP Port
The default value setting is 37777. You can enter the value according to
your actual situation.
UDP Port
The default value setting is 37778. You can enter the value according to
your actual situation.
HTTP Port
The default value setting is 80. You can enter the value according to your
actual situation.
If you enter other value, for example, 70, and then you should enter 70
after the IP address when logging in the Device by browser.
RTSP Port
The default value setting is 554. You can enter the value according to
your actual situation.
POS Port
Data transmission. The value range is from 1 through 65535. The default
value is 38800.
NTP Server Port
The default value setting is 123. You can enter the value according to
your actual situation.
HTTPS Port
HTTPS communication port. The default value setting is 443. You can
enter the value according to your actual situation.
Click Apply to complete the settings.
5.15.1.3 Configuring Wi-Fi Connection Settings
You can make wireless connection between the Device and the other devices in the same network
through Wi-Fi settings, facilitating the devices connection and mobility.
Only the Device with Wi-Fi module supports this function.
Select Main Menu > NETWORK > Wi-Fi.