21
Room number must be the same with VTH Short No., which is configured when adding
VTHs on the VTO web interface. Otherwise, it will fail to connect to the VTO.
When there are extension VTHs, room numbers must end with #0. Otherwise, it will fail
to connect to the VTO.
As an extension VTH.
1) Switch Main to Extension.
2) Enter the room number (such as 101#1), Main VTH IP (IP address of the main VTH)
and other information, and then tap OK.
Main VTH Username and Main VTH PWD are the username and password of main VTH.
Default user name is admin, and the password is the one set during initialization.
Turn on the following functions as needed.
SSH: The debugging terminal will connect to the VTH remotely through SSH protocol.
Security Mode: Log in to the VTO in a secured way.
Password Protection: Encrypt the password before sending out.
It is recommended to turn off SSH, and turn on security mode and password protection.
Otherwise, the device might be exposed to security risks and data leakage.
Tap OK.
3.1.2.4 SIP Server
Configure SIP server information to connect to other devices.
On the main interface, tap Setting for more than 6 seconds.
Enter the password and tap OK.
Tap SIP Server.
SIP server
Configure the parameters.