It includes instant alarm, delay alarm, bypass and remove.
Instant alarm: in case of alarm after arm, produce alarm sound at once and
enters alarm status.
Delay alarm: in case of alarm after arm, enter alarm status after some time.
Within the time period, you can disarm and cancel the alarm.
Bypass: this area is shielded from this arm. After disarm, this area will restore
normal working status.
Remove: this area is invalid during arm/disarm.
An zone under “Remove” status cannot be bypassed.
After entering delay, when armed area triggers an alarm,
entering armed area from non-armed area within the delay
time period will not lead to linkage alarm. Linkage alarm will
be produced if delay time comes to an end and it is not
disarmed.
Delay is only valid
to the areas of
“delay alarm”.
After arm, “delay alarm” area will enter arm status at the
end of “exit delay”.
If multiple areas set the exit delay, interface prompt will
conform to maximum delay time.
Table 6-2
Press [OK] to complete setting.
6.2.3.2 Wireless Zone
Only devices with wireless function have this function.
Add, delete and set wireless zones.
Press [Setting].
The system pops up “Password” prompt box.
Input login password and press [OK].
Default login password is 123456. Please refer to “6.2.6.3 Password Setting” for
details.
Select “Alarm > Wireless Zone”.
The system displays “Wireless Zone” interface, as shown in Figure 6-9.