9 | Electrical installation
Installer reference guide
127
ERLA11~16D + EBVH16SU23D
Daikin Altherma 3 R F
4P655196-1A – 2022.05
Item Description
Changeover to external
heat source control
See "9.3.8To connect the changeover to external
heat source"[4138].
Power consumption digital
inputs
See "9.3.9To connect the power consumption
digital inputs"[4139].
Safety thermostat See "9.3.10To connect the safety thermostat
(normally closed contact)"[4140].
Smart Grid See "9.3.11To connect a Smart Grid"[4141].
Room thermostat (wired or
wireless)
See below table.
Wires: 0.75mm²
Maximum running current: 100mA
For the main zone:
[2.9] Control
[2.A] Ext thermostat type
For the additional zone:
[3.A] Ext thermostat type
[3.9] (read-only) Control
Heat pump convector There are different controllers and setups
possible for the heat pump convectors.
Depending on the setup, you also need to
implement a relay (field supply, see
addendum book for optional equipment).
For more information, see:
Installation manual of the heat pump
convectors
Installation manual of the heat pump
convector options
Addendum book for optional equipment
Wires: 0.75mm²
Maximum running current: 100mA
For the main zone:
[2.9] Control
[2.A] Ext thermostat type
For the additional zone:
[3.A] Ext thermostat type
[3.9] (read-only) Control