EasyManua.ls Logo

Daikin Altherma 3 R F - Page 128

Daikin Altherma 3 R F
312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 | Electrical installation
Installer reference guide
128
ERLA11~16D + EBVH16SU23D
Daikin Altherma 3 R F
4P655196-1A – 2022.05
Item Description
Remote outdoor sensor See:
Installation manual of the remote outdoor
sensor
Addendum book for optional equipment
Wires: 2×0.75mm²
[9.B.1]=1 (External sensor = Outdoor)
[9.B.2] Ext. amb. sensor offset
[9.B.3] Averaging time
Remote indoor sensor See:
Installation manual of the remote indoor
sensor
Addendum book for optional equipment
Wires: 2×0.75mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset
Human Comfort Interface See:
Installation and operation manual of the
Human Comfort Interface
Addendum book for optional equipment
Wires: 2×(0.75~1.25mm²)
Maximum length: 500m
[2.9] Control
[1.6] Room sensor offset
LAN adapter See:
Installation manual of the LAN adapter
Addendum book for optional equipment
Wires: 2×(0.75~1.25mm²). Must be
sheathed.
Maximum length: 200m
See installation manual of the LAN adapter
WLAN cartridge See:
Installation manual of the WLAN cartridge
Installer reference guide
[D] Wireless gateway