Breadcrumb Field code Setting name Range, step
Default value
Date Value
Field settings table
Installer setting at variance with
default value
9.9.5 [5-06] R/W 0~50 A, step: 1 A
50
A
9.9.6 [5-07] R/W 0~50 A, step: 1 A
50
A
9.9.7 [5-08] R/W 0~50 A, step: 1 A
50
A
9.9.8 [5-09] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.9 [5-09] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.A [5-0A] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.B [5-0B] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.C [5-0C] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.D [4-01]
0: None
1: BSH
2: BUH
9.9.F [7-07] R/W
0: Disabled
1: Enabled
└─ Energy metering
9.A.1 [D-08] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
p
ulse/kWh
9.A.2 [D-09] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
8: 1 pulse/m³ (gas meter)
9: 10 pulses/m³ (gas meter)
10: 100 pulses/m³ (gas meter)
└─ Sensors
9.B.1 [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
9.B.2 [2-0B] R/W -5~5°C, step: 0,5°C
0°C
9.B.3 [1-0A] R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
└─ Bivalent
9.C.1 [C-02] R/W
0: No
1: Bivalent throu
g
h header
9.C.2 [7-05] R/W
0: Very high
1: High
2: Medium
3: Low
4: Ver
y
low
9.C.3 [C-03] R/W -25~25°C, step: 1°C
0°C
9.C.4 [C-04] R/W 2~10°C, step 1°C
3°C
Installer settings
9.D [C-09] R/W
0: Normally open
1: Normall
y
closed
9.E [3-00] R/W 0: No
1: Yes
9.F [E-08] R/W 0: Disabled
1: Enabled
9.G R/W 0: No
1: Yes
└─ Overview field settings
9.I [0-00] R/W [9-05]~min(45,[9-06])°C, step: 1°C
25°C
9.I [0-01] R/W [9-05]~[9-06], step: 1°C
[2-0D]=0:
40°C
[2-0D]=1:
45°C
[2-0D]=2:
55°C
9.I [0-02] R/W 10~25°C, step: 1°C
15°C
9.I [0-03] R/W -40~5°C, step: 1°C
-10°C
9.I [0-04] R/W [9-07]~[9-08]°C, step: 1°C
[2-0D]=0:
18°C
[2-0D]=1:
5°C
[2-0D]=2:
18°C
9.I [0-05] R/W [9-07]~[9-08]°C, step: 1°C
22°C
9.I [0-06] R/W 25~43°C, step: 1°C
35°C
9.I [0-07] R/W 10~25°C, step: 1°C
20°C
9.I [0-0B] R/W
35~[6-0E]°C, step: 1°C
50°C
Limit 2
Limit 3
Limit 4
Limit
Limit 1
Limit 2
Limit 3
Limit 4
Priority heater
Electricity meter 1
Electricity meter 2 / PV meter
BBR16 activation*
*BBR16 settings are only visible when the language of the user interface is set to
Swedish.
External sensor
Ext. amb. sensor offset
Averaging time
Bivalent
Boiler efficiency
Temperature
Hysteresis
Alarm output
Auto restart
Power saving function
Disable protections
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating WD curve.
Low ambient temp. for LWT add zone heating WD curve.
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
High ambient temp. for LWT add zone cooling WD curve.
Low ambient temp. for LWT add zone cooling WD curve.
Leaving water value for high ambient temp. for DHW WD curve.
(*1) *6V_(*2) *9W_(*3) EBB*_(*4) EBV*_
(*5) *X*_(*6) *H*_(*7) *11*_(*8) *16*_
(*9) *SU*_(*10) *18*_(*11) *23*