8 | Configuration
Installer reference guide
158
ERGA04~08DAV3(A) + EHBH/X04+08DA*V7
Daikin Altherma 3 R W
4P618958-1 – 2020.03
If you want to… Then…
Manually activate a quiet
mode level
Select the applicable quiet mode
level. Example: Most quiet.
Use and program a quiet mode
schedule
Select Automatic.
Go to [7.4.2] Schedule and
program the schedule. For more
information about scheduling, see
"8.3.7Schedule screen:
Example"[4114].
Usage example: Baby is sleeping in the afternoon
If you are in the following situation:
▪ You have programmed a quiet mode schedule:
- During the night: Most quiet.
- During the day: Off to ensure the heating/cooling capacity of the system.
▪ However, during the afternoon the baby is sleeping and you want it to be quiet.
Then you can do the following:
1 Go to [7.4.1]: User settings > Quiet > Activation.
2 Select Most quiet.
Advantage:
The outdoor unit runs in its most quiet level.
Electricity prices and gas price
Only applicable in combination with the bivalent function. See also
"Bivalent"[4174].
# Code Description
[7.5.1] N/A Electricity price > High
[7.5.2] N/A Electricity price > Medium
[7.5.3] N/A Electricity price > Low
[7.6] N/A Gas price
INFORMATION
Electricity price can only be set when bivalent is ON ([9.C.1] or [C-02]). These values
can only be set in menu structure [7.5.1], [7.5.2] and [7.5.3]. Do NOT use overview
settings.
To set the gas price
1 Go to [7.6]: User settings > Gas price.
2 Select the correct gas price.
3 Confirm the changes.
INFORMATION
Price value ranging from 0.00~990valuta/kWh (with 2 significant values).