Daikin Altherma ERHQ011-014-016BA - Electrical Connection Diagram

Daikin Altherma ERHQ011-014-016BA
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 Technical data
Installer reference guide
109
ERHQ+ERLQ011~016 + EHBH/X11+16CB
Daikin Altherma – Low temperature split
4P384974-1 – 2015.01
Electrical connection diagram
For more details, please check the unit wiring.
1
1
2
2
2
2
2x0.75
230 V
230 V
230 V
230 V
230 V
A8P: X801M: 4-5
A8P: X801M: 3-5
A8P: X801M: 2-5
A8P: X801M: 1-5
230 V
X7M F2B
SPST:
X2M: 8-9-10
A4P: X4
X2M: 28
X9A (PCB A1P)
X2M: 13-14
X5M: 3-4
X2M: 30-31
A4P:Y2
X2M:29
230 V
230 V
X5M: 9-10
X5M: 7-8
X2M: 34-35
A4P: X1-X2
A4P: Y3
X2M: 29
A4P: Y1
X2M: 28
A4P: Y2
X2M: 29
X5M: 5-6
X5M: 1-2
X2M: 32-33
230 V
230 V
230 V
230 V
230 V
230 V
A3P: X1M: C-com-H
230 V
2x0.75
X11M: 3-4-5-6
230 V
A3P: X1M: 1-3
A4P: X1M: H-C-com
X2M: L-N
230 V
2x0.75
X1M:
1-2-3
X1Y: 1-2
2x0.75
X1M: 1-2-3
4D090420
Only for normal power supply installation
unit preferential kWh rate power supply:
400 V or 230 V + earth
Only for preferential kWh rate power supply installation
Power supply
5 or 3 core
5 or 3 core
normal kWh rate power supply for indoor unit: 230 V
3 core
2 core
Preferential kWh rate power supply contact
backup heater power supply (3/6/9 kW): 400 V or 230 V + earth
unit power supply: 400 V or 230 V + earth
Optional parts (*KHW*)
booster heater power supply (3 kW): 230 V + earth
4 or 3
core
DOMESTIC HOT
WATER TANK
3 core
2way valve
X5M
Q*L
clixon
X6M
Q2L - clixon
booster heater
Booster heater
R5T - thermistor
water temperature
X8M
Q*L
clixon
2 core
5 core
5Gx2.5
2 core
signal
solar pump
M3S (when *KHW is installed)
selection domestic hot water-floor heating
FIELD SUPPLY
Power limitation
demand input 4
Power limitation
demand input 3
Power limitatio
n
demand input 2
Power limitation
demand input 1
2 core
2 core
2 core
2 core
Only for *KRP1AHTA
3WAY VALVE
Only for *KSOLHWAV1
X4M: 1-2-earth
Only for *KHWSU*V3
F2B: L-N + earth
F1B: L1-L2-L3
or L-N + earth
INDOOR
UNIT
STANDARD PART
OPTIONAL PART
OPTIONAL PAR
T
FIELD SUPPLY
OUTDOOR UNIT
Cooling/heating
On/OFF output
NO valve: X2M: 6-7
NC valve: X2M: 5-7
Changeover to
ext. heat source output
Solar input
Alarm output
main: X2M: 1-4
add: X2M: 1a-4
main: X2M: 1-2-3-4
add: X2M: 1a-2a-3-4
main: X2M: 1-2-4
add: X2M: 1a-2a-4
Only for *KSR3PA option
Ext. heat source (eg boiler)
BSK: 1-2 solar interlock
alarm indication
Only for *KRP1HB* & *KSOLHWAV1
2 core
2 core
2 core
2 core
signal
2WAY VALVE
Electricity meter
pulse i
nput 2
Electricity meter
pulse input 1
Circulation pump
for DHW
M2S (*KHBX units)
for cooling mode
2 core
2 core
signal
2 core
2 core
signal
Only for KRCS01-1 or EKRSCA1
external thermistor
(indoor or outdoor)
2 core
EXTERNAL ROOM THERMOSTAT / HEAT PUMP CONVECTOR
(main and/or additional zone)
Only for *KRTW
(wired room thermostat)
3 core for C/H operation
2 core for H only operation
A2P: P1-P2 user interface
communication
2 core
Only for
(heat pump convec
tor)
Only for *KRTR
(wireless room thermostat)
4 core
5 core for C/H operation
4 core for H only operation
communication
2 core
Only for *KRUCBL*
A2P: P1-P2 user interface
Notes:
- In case of signal cable: keep minimum distance to power cables > 5 cm
- Available heaters depending on model: see combination table
Only for *KRTETS
R2T
External sensor
(floor or ambient)
2 core
(3m included)
signal
Cooling/heating
On/OFF output
Only for *KBPHT*
& dep
ending on model
X1M: L1-L2-L3-N-earth
or L-N-earth
Bottom plate heater
2 core3 core
STANDARD PART

Table of Contents