14 Technical data
Installer reference guide
122
ERHQ+ERLQ011~016 + EHBH/X11+16CB
Daikin Altherma – Low temperature split
4P384974-1 – 2015.01
Nominal capacity and nominal input: ERLQ_W1
Heating only type Reversible type
Indoor units EHBH11+16/EHVH11+16 EHBX11+16/EHVX11+16
Outdoor units ERLQ011CAW1 ERLQ014CAW1 ERLQ016CAW1 ERLQ011CAW1 ERLQ014CAW1 ERLQ016CAW1
Cooling and heating floor program
Nominal
heating
(a)
Capacity 11.2kW 14.5kW 16kW 11.2kW 14.5kW 16kW
Power input 2.43kW 3.37kW 3.76kW 2.43kW 3.37kW 3.76kW
COP 4.6 4.3 4.25 4.6 4.3 4.25
Maximum
heating
(c)
Capacity 8.6kW 10.6kW 11.4kW 8.6kW 10.6kW 11.4kW
Power input 3.13kW 4.00kW 4.32kW 3.13kW 4.00kW 4.32kW
COP 2.75 2.65 2.64 2.75 2.65 2.64
Nominal
cooling
(a)
Capacity 15.05kW 16.06kW 16.76kW
Power input 4.53kW 5.43kW 6.16kW
EER 3.32 2.96 2.72
Fan coil program
Nominal
heating
(b)
Capacity 11.00kW 13.60kW 15.20kW 11.00kW 13.60kW 15.20kW
Power input 3.10kW 4.10kW 4.66kW 3.10kW 4.10kW 4.66kW
COP 3.55 3.32 3.26 3.55 3.32 3.26
Maximum
heating
(d)
Capacity 8.60kW 10.80kW 10.90kW 8.60kW 10.80kW 10.90kW
Power input 4.10kW 5.19kW 5.22kW 4.10kW 5.19kW 5.22kW
COP 2.10 2.08 2.09 2.10 2.08 2.09
Nominal
cooling
(b)
Capacity 11.72kW 12.55kW 13.12kW
Power input 4.31kW 5.08kW 5.73kW
EER 2.72 2.47 2.29
(a) In heating: Ambient temperature DB/WB 7°C/6°C – leaving water condenser 35°C (ΔT=5°C). In cooling: Ambient temperature 35°C – leaving
water evaporator 18°C (ΔT=5°C)
(b) In heating: Ambient temperature DB/WB 7°C/6°C – leaving water condenser 45°C (ΔT=5°C). In cooling: Ambient temperature 35°C – leaving
water evaporator 7°C (ΔT=5°C)
(c) In heating: Ambient temperature DB –7°C (RH 85%) – leaving water condenser 35°C.
(d) In heating: Ambient temperature DB –7°C (RH 85%) – leaving water condenser 45°C.
Technical specifications: ERLQ_W1
Heating only type Reversible type
Indoor units EHBH11+16/EHVH11+16 EHBX11+16/EHVX11+16
Outdoor units ERLQ011CAW1 ERLQ014CAW1 ERLQ016CAW1 ERLQ011CAW1 ERLQ014CAW1 ERLQ016CAW1
Casing
Colour Ivory white
Material Painted galvanised steel plate
Dimensions
Packing (H×W×D) 1524×980×420mm
Unit (H×W×D) 1345×900×320mm
Weight
Machine weight 114kg
Gross weight 129kg
Packing
Material EPS, carton, wood, PE (straps)
Weight 15kg
Heat exchanger
Specifications Length 857mm
Nr. of rows 2
Fin pitch 1.4mm
Nr. of passes 7
Face area 1.131m²
Nr. of stages 60
Empty tube
plate hole
0
Tube type Hi-XSS(8)