14.7.2 Technical specifications: Indoor unit
Technical specifications
Indoor units EHBH EHBX
11CB3V 11CB9W 16CB3V 16CB9W 11CB3V 11CB9W 16CB3V 16CB9W
Nominal input (indoor unit only) 110W 170W 110W 170W
Casing
Colour White
Material Pre-coated sheetmetal
Dimensions
Packing (H×W×D) 890×480×344mm
Unit (H×W×D) 415×650×1016mm
Weight of machine (net) 43kg 44kg 45kg 43kg 45kg 44kg 46kg
Weight of machine (packed) 46kg 47kg 46kg 48kg 47kg 48kg 47kg 49kg
Packing materials
Material EPS – carton – PP (straps)
Weight 3kg
PED
Category of unit Art. 3.3§3
(1)
Pump
Type DC motor
Nr. of speed Inverter controlled
Power input 76W 140W 76W 140W
Water side heat exchanger
Type Brazed plated
Quantity 1
Water volume 1l
Water flow rate Minimum 16l/min
(2)
Maximum 46l/min
Expansion vessel Volume 10l
Maximum
water pressure
3bar
Pre-pressure 1bar
Water filter Diameter
perforations
1
Material Copper + brass + stainless steel
Water circuit
Piping connections Ø G1-1/4 female
Safety valve 3bar
Manometer Yes
Drain valve/fill valve Yes
Shut-off valves Yes
Air purge valve Yes
Total water volume 4.0l
(3)
Refrigerant circuit
Gas side Ø15.9mm
Liquid side Ø9.5mm
Sound power level
Nominal 41dBA
(4)
44dBA
(4)
41dBA
(4)
44dBA
(4)
Sound pressure level
Nominal 27dBA
(5)
30dBA
(5)
27dBA
(5)
30dBA
(5)
Operation range