2 About the documentation
Installer reference guide
6
ERHQ+ERLQ011~016 + EHBH/X11+16CB
Daikin Altherma – Low temperature split
4P384974-1 – 2015.01
1.2.6 Electrical
DANGER: RISK OF ELECTROCUTION
Turn OFF all power supply before removing the
switch box cover, connecting electrical wiring or
touching electrical parts.
Disconnect the power supply for more than 1 minute,
and measure the voltage at the terminals of main circuit
capacitors or electrical components before servicing.
The voltage MUST be less than 50 V DC before you
can touch electrical components. For the location of the
terminals, see the wiring diagram.
Do NOT touch electrical components with wet hands.
Do NOT leave the unit unattended when the service
cover is removed.
WARNING
If NOT factory installed, a main switch or other means for
disconnection, having a contact separation in all poles
providing full disconnection under overvoltage category III
condition, shall be installed in the fixed wiring.
WARNING
ONLY use copper wires.
Make sure the field wiring complies with the applicable
legislation.
All field wiring must be performed in accordance with
the wiring diagram supplied with the product.
NEVER squeeze bundled cables and make sure they
do not come in contact with the piping and sharp
edges. Make sure no external pressure is applied to the
terminal connections.
Make sure to install earth wiring. Do NOT earth the unit
to a utility pipe, surge absorber, or telephone earth.
Incomplete earth may cause electrical shock.
Make sure to use a dedicated power circuit. NEVER
use a power supply shared by another appliance.
Make sure to install the required fuses or circuit
breakers.
Make sure to install an earth leakage protector. Failure
to do so may cause electric shock or fire.
When installing the earth leakage protector, make sure
it is compatible with the inverter (resistant to high
frequency electric noise) to avoid unnecessary opening
of the earth leakage protector.
Install power cables at least 1metre away from televisions or radios
to prevent interference. Depending on the radio waves, a distance of
1metre may not be sufficient.
WARNING
After finishing the electrical work, confirm that each
electrical component and terminal inside the electrical
components box is connected securely.
Make sure all covers are closed before starting up the
unit.
NOTICE
Only applicable if the power supply is three‑phase, and the
compressor has an ON/OFF starting method.
If there exists the possibility of reversed phase after a
momentary black out and the power goes on and off while
the product is operating, attach a reversed phase
protection circuit locally. Running the product in reversed
phase can break the compressor and other parts.
2 About the documentation
2.1 About this document
Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set
consists of:
Document Contains… Format
General
safety
precautions
Safety instructions that
you must read before
installing
Paper (in the box of the
indoor unit)
Indoor unit
installation
manual
Installation instructions
Outdoor unit
installation
manual
Installation instructions Paper (in the box of the
outdoor unit)
Installer
reference
guide
Preparation of the
installation, technical
specifications, good
practices, reference data,
Digital files on http://
www.daikineurope.com/
support-and-manuals/
product-information/.
Addendum
book for
optional
equipment
Additional info about how
to install optional
equipment
Paper (in the box of the
indoor unit)
Digital files on http://
www.daikineurope.com/
support-and-manuals/
product-information/.
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
2.2 Installer reference guide at a
glance
Chapter Description
General safety
precautions
Safety instructions that you must read
before installing
About the documentation What documentation exists for the
installer
About the box How to unpack the units and remove
their accessories
About the units and
options
How to identify the units
Possible combinations of units and
options
Application guidelines Various installation setups of the system
Preparation What to do and know before going
on‑site
Installation What to do and know to install the
system
Configuration What to do and know to configure the
system after it is installed
Commissioning What to do and know to commission the
system after it is configured
Hand‑over to the user What to give and explain to the user
Maintenance and service How to maintain and service the units
Troubleshooting What to do in case of problems

Table of Contents

Related product manuals