4 About the units and options
Installer reference guide
8
ERHQ+ERLQ011~016 + EHBH/X11+16CB
Daikin Altherma – Low temperature split
4P384974-1 – 2015.01
a
a
a General safety precautions, indoor unit installation manual,
operation manual and addendum book for optional
equipment
INFORMATION
Do NOT throw away the upper cardboard cover. On the
outside of the cardboard cover, the installation pattern is
printed.
3.3.2 To remove the accessories from the
indoor unit
The general safety precautions, the indoor unit installation manual,
the operation manual and the addendum book for optional
equipment are located in the upper part of the box. Follow the
procedure below to remove the other accessories.
1 Remove the tape.
2 Tilt the bottom side of the front panel upwards and remove it.
3 Remove the accessories.
g
e+f
h
a b c d
f
e g
h
a General safety precautions
b Addendum book for optional equipment
c Indoor unit installation manual
d Operation manual
e Sealing ring for shut-off valve
f Shut-off valve
g User interface cover
h Top plate of indoor unit
4 About the units and options
4.1 Overview: About the units and
options
This chapter contains information about:
Identifying the outdoor unit
Identifying the indoor unit
Combining outdoor and indoor units
Combining the outdoor unit with options
Combining the indoor unit with options
4.2 Identification
NOTICE
When installing or servicing several units at the same time,
make sure NOT to switch the service panels between
different models.

Table of Contents