14 Technical data
Installer reference guide
116
ERHQ+ERLQ011~016 + EHBH/X11+16CB
Daikin Altherma – Low temperature split
4P384974-1 – 2015.01
Heating only type Reversible type
Indoor units EHBH11+16/EHVH11+16 EHBX11+16/EHVX11+16
Outdoor units ERHQ011BAW1 ERHQ014BAW1 ERHQ016BAW1 ERHQ011BAW1 ERHQ014BAW1 ERHQ016BAW1
External static pressure
(maximum)
—
Motor Quantity 2
Model Brushless DC motor
Position —
Speed
(nomin
al at
230V)
Nr. of
steps
8
Cooling — 780rpm
Heating 760rpm
Output 70W
Drive Direct drive
Compressor
Quantity 1
Motor Model JT1G-VDYR@S
Type Hermetically sealed scroll compressor
Speed —
Output 2200W
Starting method Inverter driven
Crankcase
heater
33W
Operation range
(a)
Heating
(outdoor unit)
(b)
Minimum –25°CDB
Maximum 35°CDB
Cooling Minimum — 10°CDB
Maximum — 46°CDB
Domestic hot
water (outdoor
unit)
(c)
Minimum –20°CDB
Maximum 35°CDB
Sound level
Nominal –
Heating
(d)
Sound power 64dBA 64dBA 66dBA 64dBA 64dBA 66dBA
Sound
pressure
(f)
51dBA 51dBA 52dBA 51dBA 51dBA 52dBA
Nominal –
Cooling
(e)
Sound power — 64dBA 66dBA 69dBA
Sound
pressure
(f)
— 50dBA 52dBA 54dBA
Night quiet -
Heating
Sound
pressure
(f)
42dBA 42dBA 43dBA 42dBA 42dBA 43dBA
Night quiet -
Cooling
Sound
pressure
(f)
— 45dBA 45dBA 46dBA
Refrigerant
Type R410A
Charge 2.95kg
Control Expansion valve (electronic type)
Nr. of circuits 1
Refrigerant oil
Type Daphne FVC68D
Charged volume 1.0l
Piping connections
Liquid Quantity 1
Type Flare connection
Diameter (OD) Ø9.52mm
Gas Quantity 1
Type Flare connection
Diameter (OD) Ø15.9mm