14 Technical data
Installer reference guide
128
ERHQ+ERLQ011~016 + EHBH/X11+16CB
Daikin Altherma – Low temperature split
4P384974-1 – 2015.01
Indoor units EHBH EHBX EHBH EHBX EHBH EHBX EHBH EHBX
11CB3V 11CB9W 16CB3V 16CB9W 11CB3V 11CB9W 16CB3V 16CB9W
For connection
with optional
FWXV (demand
input and output)
Quantity of
wires
4
Type of wires 100mA, minimum 0.75mm
2
(1) PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC.
(2) Operation area is extended to lower flow rates only in case the unit operated with heat pump only. (Not in startup, no backup heater operation, no
defrost operation).
(3) Including piping + PHE + backup heater; excluding expansion vessel.
(4) DB/WB7°C/6°C – LWC 35°C (DT=5°C)
(5) The sound pressure level is measured in an anechoice room at 1m distance from the unit. It is a relative value, depending on the distance and
acoustic environment. The sound pressure level mentioned is maximum possible value inside operation range of unit.
(6) >50°CBSH only, no heat pump operation.
(7) Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the
outdoor unit. The optional domestic hot water tank has a separate power supply.
(8) Select diameter and type according to national and local regulations.
(9) Select diameter and type according to national and local regulations. Equipment complying with EN/IEC61000-3-12: European/technical
standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input >16A and ≤75A per
phase.
(10) Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the
outdoor unit. The optional domestic hot water tank has a separate power supply.
(11) >50°Cbooster heater only, no heat pump operation.
Electrical specifications of backup heater and booster heater (only for EKHW)
Type 3V 9W
Backup heater
Capacity setting 3kW 6kW 3kW 6kW 9kW
Capacity stage 1 2 1 2
Capacity stage 1 3kW
Capacity stage 2 6 6 9
Minimum delay between stages See figure1 See figure2
Power supply
(1)
1~50Hz 3~50Hz 1~50Hz 3~50Hz
Voltage 230V 400V
Nominal current 13A 15.1A 13A 26A 8.7A 13A
Z
max
(backup heater)
(2)
Minimum S
sc
value
(1)
Booster heater (optional EKHW models)
Capacity setting 3kW
Capacity stage 1
Minimum time delay between stages See figure3
Nominal current V3 26 (13+13)A 28.1
(15.1+13)A
26 (13+13)A 39 (26+13)A 21.7
(8.7+13)A
26 (13+13)A
Z2 16.2
(8.7+7.5)A
20.5
(13+7.5)A
Minimum S
sc
value V3
(3)
Z2
(3)
(1) The above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied
with the outdoor unit. The optional domestic hot water tank has a separate power supply.
(2) In accordance with EN/IEC61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is
connected only to a supply Zsysnode:1261007898681260911529≤Zmaxnode:1261007898681260911528.
Figure1: Backup heater (*3V), minimum time delay between
stages
1 min 10 min
a
b
t
a Capacity
b Stage1
t Time
Figure2: Backup heater (*9W), minimum time delay between
stages
1 min 1 min 10 min10 sec 0 sec6 min*
a
b
c
t
a Capacity
b Stage1
c Stage2
(1)The equipment complies with EN/IEC61000-3-12.