Date Value
User settings
└─ Preset values
└─ Room temperature
7.4.1.1 R/W [3-07]~[3-06], step: A.3.2.4
21°C
7.4.1.2 R/W [3-07]~[3-06], step: A.3.2.4
19°C
7.4.1.3 R/W [3-08]~[3-09], step: A.3.2.4
24°C
7.4.1.4 R/W [3-08]~[3-09], step: A.3.2.4
26°C
└─ LWT main
7.4.2.1 [8-09] R/W [9-01]~[9-00], step: 1°C
35°C
7.4.2.2 [8-0A] R/W [9-01]~[9-00], step: 1°C
33°C
7.4.2.3 [8-07] R/W [9-03]~[9-02], step: 1°C
18°C
7.4.2.4 [8-08] R/W [9-03]~[9-02], step: 1°C
20°C
7.4.2.5 R/W -10~10°C, step: 1°C
0°C
7.4.2.6 R/W -10~10°C, step: 1°C
-2°C
7.4.2.7 R/W -10~10°C, step: 1°C
0°C
7.4.2.8 R/W -10~10°C, step: 1°C
2°C
└─ Tank temperature
7.4.3.1 [6-0A] R/W 30~[6-0E]°C, step: 1°C
60°C
7.4.3.2 [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
7.4.3.3 [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
└─ Quiet level
7.4.4 R/W
0: Level 1
1: Level 2
2: Level 3
└─ Electricity price
7.4.5.1 [C-0C]
[D-0C]
R/W 0,00~990/kWh
0/kWh
7.4.5.2 [C-0D]
[D-0D]
R/W 0,00~990/kWh
0/kWh
7.4.5.3 [C-0E]
[D-0E]
R/W 0,00~990/kWh
0/kWh
└─ Fuel price
7.4.6 R/W 0,00~990/kWh
0,00~290/MBtu
8,0/kWh
└─ Set weather dependent
└─ Main
└────────────────── Set weather-dependent heating
7.7.1.1 [1-00] Set weather-dependent heating Low ambient temp. for LWT main zone heating
WD curve.
R/W -40~5°C, step: 1°C
-10°C
7.7.1.1 [1-01] Set weather-dependent heating High ambient temp. for LWT main zone heating
WD curve.
R/W 10~25°C, step: 1°C
15°C
7.7.1.1 [1-02] Set weather-dependent heating Leaving water value for low ambient temp. for
LWT main zone heating WD curve.
R/W
[9-01]~[9-00]°C, step: 1°C
35°C
7.7.1.1 [1-03] Set weather-dependent heating Leaving water value for high ambient temp. for
LWT main zone heating WD curve.
R/W [9-01]~min(45, [9-00])°C , step: 1°C
25°C
└────────────────── Set weather-dependent cooling
7.7.1.2 [1-06] Set weather-dependent cooling Low ambient temp. for LWT main zone cooling
WD curve.
R/W 10~25°C, step: 1°C
20°C
7.7.1.2 [1-07] Set weather-dependent cooling High ambient temp. for LWT main zone cooling
WD curve.
R/W
25~43°C, step: 1°C
35°C
7.7.1.2 [1-08] Set weather-dependent cooling Leaving water value for low ambient temp. for
LWT main zone cooling WD curve.
R/W [9-03]~[9-02]°C, step: 1°C
22°C
7.7.1.2 [1-09] Set weather-dependent cooling Leaving water value for high ambient temp. for
LWT main zone cooling WD curve.
R/W [9-03]~[9-02]°C, step: 1°C
18°C
└─ Additional
└────────────────── Set weather-dependent heating
7.7.2.1 [0-00] Set weather-dependent heating Leaving water value for high ambient temp. for
LWT add zone heating WD curve.
R/W [9-05]~min(45,[9-06])°C, step: 1°C
35°C
7.7.2.1 [0-01] Set weather-dependent heating Leaving water value for low ambient temp. for
LWT add zone heating WD curve.
R/W [9-05]~[9-06]°C, step: 1°C
45°C
7.7.2.1 [0-02] Set weather-dependent heating High ambient temp. for LWT add zone heating
WD curve.
R/W 10~25°C, step: 1°C
15°C
7.7.2.1 [0-03] Set weather-dependent heating Low ambient temp. for LWT add zone heating
WD curve.
R/W -40~5°C, step: 1°C
-10°C
└────────────────── Set weather-dependent cooling
7.7.2.2 [0-04] Set weather-dependent cooling Leaving water value for high ambient temp. for
LWT add zone cooling WD curve.
R/W [9-07]~[9-08]°C, step: 1°C
8°C
7.7.2.2 [0-05] Set weather-dependent cooling Leaving water value for low ambient temp. for
LWT add zone cooling WD curve.
R/W [9-07]~[9-08]°C, step: 1°C
12°C
7.7.2.2 [0-06] Set weather-dependent cooling High ambient temp. for LWT add zone cooling
WD curve.
R/W 25~43°C, step: 1°C
35°C
7.7.2.2 [0-07] Set weather-dependent cooling Low ambient temp. for LWT add zone cooling
WD curve.
R/W 10~25°C, step: 1°C
20°C
Installer settings
└─ System layout
└─ Standard
A.2.1.1 [E-00] R/O 0~5
0: LT s