Functions for FTX, FVXS Series SiUS091601EA
47 Part 4 Functions and Control
Caution
FVXS series
3-D Airflow FTX18/24UVJU only
Alternative repetition of vertical and horizontal swing motions enables uniform air-conditioning of
the entire room.
When the horizontal swing and vertical swing are both set to automatic operation, the airflow
becomes 3-D airflow. The horizontal and vertical swing motions are alternated and the airflow
direction changes in the order shown in the following diagram.
(1) The vertical blades (louvers) move from the right to the left.
(2) The horizontal blades (flaps) move downward.
(3) The vertical blades (louvers) move from the left to the right.
(4) The horizontal blades (flaps) move upward.
Airflow Selection
Setting
FVXS Series
Airflow direction can be set with the airflow selection switch.
Open the front panel.
Before opening the front panel, be sure to stop the operation and turn the breaker off.
Do not touch the aluminum fins (indoor heat exchanger) inside the indoor unit, as it may result in
injury.
Flap (up and down)
Cooling/Dry Heating
Upward airflow
limit OFF
R4003397
R4003396
Upward airflow
limit ON
R4003394 R4003394
25°
90°
40°
90°
90°
20°
90°
20°
(R19554)
(2)
(4)
(3)
(1)
Air is blown from the upper outlet only.
Front panel
The blow pattern is automatically decided
depending on mode and conditions.
(Recommended and factory set.)
(R17866)

Table of Contents

Other manuals for Daikin FDMQ-R Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FDMQ-R Series and is the answer not in the manual?

Daikin FDMQ-R Series Specifications

General IconGeneral
BrandDaikin
ModelFDMQ-R Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals