Functions SiUS04-904
List of Functions 3
SEER 13 Functions:
Category Functions
FTXS09/12HVJU
RX09/12FAVJU
FTXS15/18/24HVJU
RX15/18/24FVJU
Category Functions
FTXS09/12HVJU
RX09/12FAVJU
FTXS15/18/24HVJU
RX15/18/24FVJU
Basic
Function
Inverter (with Inverter Power Control) Health & Air
Cleaning
Air-Purifying Filter
Operation Limit for Cooling (°FDB)
14~
115
14~
115
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°FWB)
5~
64
5~
64
Air-Purifying Filter with Photocatalytic
Deodorizing Function

PAM Control 
Titanium Apatite Photocatalytic
Air-Purifying Filter
——
Compressor Oval Scroll Compressor
Swing Compressor  Air Filter (Prefilter) 
Rotary Compressor Wipe-clean Flat Panel 
Reluctance DC Motor  Washable Grille
Comfortable
Airflow
Power-Airflow Louvers Filter Cleaning Indicator
Power-Airflow Dual Louvers  Good-Sleep Cooling Operation
Power-Airflow Diffuser Timer 24-Hour ON/OFF Timer 
Wide-Angle Louvers  Night Set Mode 
Auto-Swing; Horizontal Louvers
operate vertically (Up and Down)

Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure) 
Vertical Fins operate horizontally; Auto-
Swing (Right and Left)
Self-Diagnosis (Digital, LED) Display 
3-D Airflow Wiring Error Check
Comfort Airflow Mode
Anticorrosion Treatment of Outdoor
Heat Exchanger

Comfort
Control
Auto Fan Speed 
Indoor Unit Quiet Operation Flexibility
Multi-Split / Split Type Compatible
Indoor Unit
Night Quiet Mode (Automatic)
Outdoor Unit Quiet Operation (Manual)  Flexible Voltage Correspondence
INTELLIGENT EYE  High Ceiling Application
Quick Warming Function  Chargeless
33ft 33ft
Hot-Start Function  Either Side Drain (Right or Left) 
Automatic Defrosting  Power Selection
Operation
Automatic Operation 
Remote
Control
5-Rooms Centralized Controller
(Option)

Program Dry Function 
Remote Control Adapter
(Normal Open-Pulse Contact) (Option)

Fan Only 
Lifestyle
Convenience
New POWERFUL Operation (Non-
Inverter)
——
Remote Control Adapter
(Normal Open Contact) (Option)

Inverter POWERFUL Operation 
Priority-Room Setting DIII-NET Compatible (Adapter) (Option) 
Cooling / Heating Mode Lock Remote
Controller
Wireless 
HOME LEAVE Operation  Wired (Option) 
Indoor Unit ON/OFF Switch 
Signal Reception Indicator 
Temperature Display
Note: : Holding Functions
— : No Functions
15/18 class

Table of Contents