SiUS04-904 RXS09/12DAVJU, RX09/12FAVJU
210 Removal Procedure
3.2 Removal of Electrical Box
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembly work.
Step
Procedure Points
Remove the top panel.
Disconnect the connector for
fan motor.
1. Removal of the electrical
box.
1
Disconnect the 2 reactor
harnesses.
2
Cut the clamp.
3
Disconnect the connector
for compressor motor
[S30].
When reassembling, coil the
excessive lead wire and hang
the loop on the hook.