SiUS04-904 FTXS15/18/24HVJU
196 Removal Procedure
3
Remove the flare nut for
liquid piping by 2
wrenches.
2. Removal of the indoor unit.
1
Detach the indoor unit
from the installation plate.
3. Removal of the piping
fixture.
1
Release the hook on the
upper side of the piping
fixture on the back of the
unit.
4. Removal of the heat
exchanger.
1
Widen the auxiliary piping
to the extent of 10°~20°.
At an angle of 10°~20°
Step
Procedure Points