12
Application Information
Cable Size
Model Unit
FT10JXV1 FT15JXV1 FT20JXV1 FT25JXV1
R09CXV1 R15CXV1 R18CXV1 R25CXV1
Power supply cable size
Number of wire
mm
2
1.5
3
1.5
3
2.5
3
2.5
3
Interconnection cable size
Number of wire
mm
2
1.5
3
1.5
3
2.5
3
2.5
3
Recommended fuse A 15 15 20 20
Model Unit
FT30FXV1
R28CXV1 R30DXV1 R30DXY1
Power supply cable size
Number of wire
mm
2
2.5
3
2.5
3
1.5
5
Interconnection cable size
Number of wire
mm
2
2.5
3
2.5
4
1.5
4
Recommended fuse A 20 20 15
Model Unit
FTY09JXV1 FTY15JXV1 FTY20JXV1 FTY25JXV1
RY09CXV1 RY15CXV1 RY20CXV1 RY25CXV1
Power supply cable size
Number of wire
mm
2
1.5
3
1.5
3
2.5
3
2.5
3
Interconnection cable size
Number of wire
mm
2
1.5
5
1.5
5
2.5
5
2.5
5
Recommended fuse A 15 15 20 20
Model Unit
FTY30FXV1 FTY30FXV1
RY28CXV1 RY30DXV1
Power supply cable size
Number of wire
mm
2
2.5
3
4
3
Interconnection cable size
Number of wire
mm
2
2.5
5
2.5
6
Recommended fuse A 20 25
DAIKIN_FT(Y).indb 12DAIKIN_FT(Y).indb 12 10/15/2012 4:27:10 PM10/15/2012 4:27:10 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTY-F series and is the answer not in the manual?

Daikin FTY-F series Specifications

General IconGeneral
BrandDaikin
ModelFTY-F series
CategoryAir Conditioner
LanguageEnglish

Related product manuals