EasyManua.ls Logo

Daikin RXR28EV1B8 - Heater Assembly, Humidifying Rotor, and Rotor Motor; Remove the heater assembly; Remove the humidifying rotor

Daikin RXR28EV1B8
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Si001275 Heater Assembly / Humidifying Rotor / Humidifying Rotor Motor
Removal Procedure 3
2. Heater Assembly / Humidifying Rotor /
Humidifying Rotor Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step Procedure Points
1. Remove the heater
assembly.
1
Remove the 4 screws
and remove the duct on
adsorption side.
2
Release the lead wire
for the humidifying
rotor motor from the
hooks.
3
Remove the 2 screws
and remove the heater
assembly.
The heater assembly should
be replaced as an assembly
set. (Disassembling of the
assembly may cause
malfunction.)
2. Remove the humidifying
rotor.
1
Release the fan motor
lead wire from the
hooks.
(R18766)
Duct on adsorption side
Heater assembly
(R18767)
Humidifying rotor motor
(R5800)
(R18768)
Fan motor lead wire
Hook
Hook

Other manuals for Daikin RXR28EV1B8

Related product manuals