SiBE05-722EE Functions
List of Functions 5
Category Functions
FLXS25/35BAVMB
RXS25/35J2V1B
FLXS25/35BAVMB
RXS25K3V1B
RXS35K2V1B
Category Functions
FLXS25/35BAVMB
RXS25/35J2V1B
FLXS25/35BAVMB
RXS25K3V1B
RXS35K2V1B
Basic
Functions
Inverter (with inverter power control)
zz
Health &
Cleanliness
Air-purifying filter
zz
Operation limit for cooling (°CDB)
–10
~ 46
–10
~ 46
Photocatalytic deodorizing filter
zz
Operation limit for heating (°CWB)
–15
~ 18
–
15
~ 18
Air-purifying filter with photocatalytic
deodorizing function (option)
zz
PAM control
zz
Titanium apatite photocatalytic
air-purifying filter
——
Standby electricity saving — —
Compressor Oval scroll compressor — — Air filter (prefilter)
zz
Swing compressor
zz
Wipe-clean flat panel — —
Rotary compressor — — Washable grille — —
Reluctance DC motor
zz
MOLD PROOF operation — —
Comfortable
Airflow
Power-airflow flap — — Good-sleep cooling operation — —
Power-airflow dual flaps — —
Timer WEEKLY TIMER operation — —
24-hour ON/OFF TIMER
zz
Power-airflow diffuser — — NIGHT SET mode
zz
Wide-angle louvers — — Worry Free
(Reliability &
Durability)
Auto-restart (after power failure)
zz
Auto-swing (up and down)
zz
Self-diagnosis (digital, LED) display
zz
Auto-swing (right and left) — — Wiring error check function — —
3-D airflow — —
Anti-corrosion treatment of outdoor
heat exchanger
zz
Comfort
Control
Auto fan speed
zz
Indoor unit quiet operation
zz
Flexibility
Multi-split/split type compatible
indoor unit
zz
NIGHT QUIET mode (automatic) — —
OUTDOOR UNIT QUIET operation
(manual)
zz
Flexible power supply
correspondence
——
INTELLIGENT EYE operation — — Chargeless 10 m 10 m
Quick warming function
(preheating control)
zz
Either side drain (right or left) — —
Hot-start function
zz
Power selection — —
Automatic defrosting
zz
Remote
Control
5-room centralized controller (option)
zz
Operation Automatic operation
zz
Remote control adaptor
(normal open pulse contact) (option)
zz
Program dry operation
zz
Fan only
zz
Remote control adaptor
(normal open contact) (option)
zz
Lifestyle
Convenience
New POWERFUL operation
(non-inverter)
——
Inverter POWERFUL operation
zz
DIII-NET compatible (adaptor)
(option)
zz
Priority-room setting — — Remote
Controller
Wireless
zz
COOL / HEAT mode lock — — Wired (option) — —
HOME LEAVE operation
zz
ECONO operation — —
Indoor unit ON/OFF button
zz
Signal receiving sign
zz
R/C with back light — —
Temperature display — —
Note: z
: Available
— : Not available
: Lower limit can be extended by cutting jumper.
(Facility use only)
Refer to page 120 for details.