ED34-862 Fan Performances
FXMQ-P 263
7
FXMQ40PVE
FXMQ50PVE
Air flow (m
3
/min)(mmH2O) (Pa) (mmH2O)
12 13 15 16 1711 14 1810
9
00 0
Lower limit of ESP
55
50
External static pressure
"L"
"H"
"HH"
10 10
100
1515
150
Upper limit of ESP
(NOTE 8)
Upper limit of
ESP by airflow
auto adjustment
2020
200
(mmH
2O) (Pa) (mmH2O)
Lower limit of ESP
by airflow auto
adjustment
Notes:
1. As for this machine, less than 10% of the volume of
blow-off air is automatically adjusted to the rated
quantity by airflow auto adjustment at the time of
installation.
2. After duct construction completion, please perform
local setting "airflow auto adjustment" by remote
controller.
3. About the local setting method of the "airflow auto
adjustment", look at the installation manual which is
attached to an indoor unit.
4. External static pressure that can adjust by "airflow
auto adjustment" function is 30Pa - 160Pa (When
air flow is HH).
5. It is not operated auto adjustment, operated in air
flow that is different from rated quantity in the case
of use out of external static pressure range
mentioned above.
6. This figure shows a fan characteristics at the time
of "HH" "H" and "L".
7. The remote controller can be used to change "HH"
"H" and "L".
8. ESP : external static pressure.
9. Please set the external static pressure of the
suction duct at 150Pa or less.
3D060577A
250
2525
Upper limit of ESP
(NOTE 8)
200
2020
Upper limit
of ESP by
airflow auto
adjustment
150
15 15
"HH"
"H"
100
1010
External static pressure
"L"
Lower limit
of ESP by
airflow auto
adjustment
50
55
Lower limit of ESP
00 0
13 2115 1816 17 201914
Notes:
1. As for this machine, less than 10% of the volume of
blow-off air is automatically adjusted to the rated
quantity by airflow auto adjustment at the time of
installation.
2. After duct construction completion, please perform
local setting "airflow auto adjustment" by remote
controller.
3. About the local setting method of the "airflow auto
adjustment", look at the installation manual which is
attached to an indoor unit.
4. External static pressure that can adjust by "airflow
auto adjustment" function is 50Pa - 200Pa (When
air flow is HH).
5. It is not operated auto adjustment, operated in air
flow that is different from rated quantity in the case
of use out of external static pressure range
mentioned above.
6. This figure shows a fan characteristics at the time of
"HH" "H" and "L".
7. The remote controller can be used to change "HH"
"H" and "L".
8. ESP : external static pressure.
9. Please set the external static pressure of the
suction duct at 150Pa or less.
(mmH2O) (Pa) (mmH2O)
Air flow (m
3
/min)(mmH2O) (Pa) (mmH2O)
3D060578A