44 PRELIMINARY Spyder 3 CL User's Manual
03-032-20008-03 DALSA
Setting Baud Rate
Purpose: Sets the speed in bps of the serial communication port.
Syntax:
sbr m
Syntax Elements:
m
Baud rate. Available baud rates are: 9600 (Default), 19200,
57600, and 115200.
Notes:
Power-on rate is always 9600 baud.
The rc (reset camera) command will not reset the camera to
the power-on baud rate and will reboot using the last used
baud rate.
Example:
sbr 57600
Select Cable
Purpose: Sets the cable parameters.
Syntax:
scb i
Syntax Elements:
i
Output compare value. Available values are: 0 to 255.
Notes:
In medium configuration, both cables must be the same length.
Only one copy of this setting is saved in the camera (rather than
with each setting).
On the lfs (load factory settings) command the cable length will
be set to the factory default of 100.
The cable parameter is a relational value. Increase the value for
longer cables, and decrease it for shorter ones.
Adjust the value until the test pattern (svm 1) is clean.
Related command
get scb
Returns the current cable parameter.
Example:
scb 75