94 PRELIMINARY Spyder 3 CL User's Manual
03-032-20008-03 DALSA
Mnemonic Syntax Parameters
Description
write PRNU coeffs
wpc
i
Write all current PRNU coefficients to
non-volatile memory, where
i is:
1 = PRNU coefficient set one
2 = PRNU coefficient set two
3 = PRNU coefficient set three
4 = PRNU coefficient set four
write user settings
wus
Write all of the user settings to non-
volatile memory.
7.18 Error Handling
The following table lists warning and error messages and provides a description and
possible cause. Warning messages are returned when the camera cannot meet the full
value of the request; error messages are returned when the camera is unable to complete
the request.
Table 16: Warning and Error Messages
Message Description
OK> SUCCESS
Warning 01: Outside
of specification>
Parameter accepted was outside of specified operating range (e.g. gain
greater than ±10 dB of factory setting).
Warning 02: Clipped
to min>
Parameter was clipped to the current operating range. Use gcp to see
value used.
Warning 03: Clipped
to max>
Parameter was clipped to the current operating range. Use gcp to see
value used.
Warning 04: Related
parameters
adjusted>
Parameter was clipped to the current operating range. Use gcp to see
value used.
Warning 07:
Coefficient may be
inaccurate A/D
clipping has
occurred>
In the region of interest (ROI) greater than 6.251% single or 1% of
averaged pixel values were zero or saturated.
Warning 08: Greater
than 1% of
coefficients have
been clipped>
A FPN/PRNU has been calculated to be greater than the maximum
allowable 511 (8).
Warning 09: Internal
line rate inconsistent
with readout time>
Message Description
Error 02:
Unrecognized
command>
Command is not available in the current access level or it is not a valid
command.
Error 03: Incorrect
number of
parameters>