EasyManua.ls Logo

d&b audiotechnik 10D - Page 91

d&b audiotechnik 10D
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Id Display text Eventlog text Description Location Possible reasons
122 CAN warning CAN warning %d
(remote flags %02X,
dbCan flags %02X)
CAN warning (External: CAN
cabling)
CAN cabling or
multiple RemIds.
124 OCA remote error OCA remote error
%u
OCA remote error Software error.
150 Speaker imp. fault (empty) Load Monitoring
impedance error
(External: speaker,
cabling)
Speaker defect,
cable.
153 Amp. low
temperature
Channel '%c': Amp.
temperature too low
(%d°C)
Amp temperature
warning
Amp Ext. conditions, sensor
fault.
160 Input fallback Input fallback (A1=
%d, A2=%d, D1=%d,
D2=%d)
Input fallback was
activated
(External: Cabling)
161 Input monitoring fault Input monitoring fault
A%d (%4.1ddBu,
threshold %4.1ddBu)
Input monitoring fault (External: Cabling) Cabling or signal
source defect.
162 Input monitoring fault Input monitoring fault
A%d (%4.1ddBu,
threshold %4.1ddBu)
Input monitoring fault
163 Input monitoring fault Input monitoring fault
A%d (%4.1ddBu,
threshold %4.1ddBu)
Input monitoring fault
164 Input monitoring fault Input monitoring fault
A%d (%4.1ddBu,
threshold %4.1ddBu)
Input monitoring fault
165 Input monitoring fault Input monitoring fault
D%d (lock %d,
%4.1ddBFS,
threshold
%4.1ddBFS)
Input monitoring fault
166 Input monitoring fault Input monitoring fault
D%d (lock %d,
%4.1ddBFS,
threshold
%4.1ddBFS)
Input monitoring fault
167 Input monitoring fault Input monitoring fault
D%d (lock %d,
%4.1ddBFS,
threshold
%4.1ddBFS)
Input monitoring fault
168 Input monitoring fault Input monitoring fault
D%d (lock %d,
%4.1ddBFS,
threshold
%4.1ddBFS)
Input monitoring fault
169 Ethernet overload Ethernet overload,
throttling active
Ethernet overload Too much network
traffic.
d&b 10D/30D Manual 1.10 en 91

Table of Contents

Related product manuals