702
CAPSULE
Cannot find
The VDR is unable to detect a fixed capsule. Check that the fixed
capsule is connected correctly. If the error persists, the fixed
capsule is probably defective.
703
CAPSULE
Cannot access
The VDR has detected a fixed capsule but is unable to get access to
the memory. If the error persists, the fixed capsule is probably
defective.
704
CAPSULE, too many
write errors
Too many write-errors (writing to the fixed capsule) have been
detected by the DPU over a period of time. The most likely cause is
communication problems. Check the cable from the DPU to the
fixed capsule.
705
CAPSULE, too many
write errors
Too many write-errors (writing to the FRM memory) have been
detected by the fixed capsule over a period of time. The most likely
cause is serious communication problems or a defective fixed
capsule.
706
CAPSULE, too many
read errors
Too many read-errors (reading back data from the fixed capsule)
have been detected by the DAU over a period of time. The VDR
was unable to write and verify data despite several attempts. The
most likely cause is serious communication problems or a defective
fixed capsule.
707
CAPSULE, too many
read errors
Too many read-errors (reading back data from the fixed capsule)
have been detected by the fixed capsule over a period of time. The
VDR was unable to write data despite several attempts. The most
likely cause is serious communication problems or a defective
fixed capsule.
708
CAPSULE
Verification failed
The VDR found too many data errors within a given interval when
verifying the data written to the fixed capsule. The fixed capsule is
probably defective.
709
CAPSULE
Record too big
The amount of data collected for a 15-second period exceeds the
maximum allowed size for the fixed capsule. This is typically
caused by receipt of too much image data. Use the “Analysis of
recorded data” utility on the BCP or in the configurator tool to
determine the cause. If the problem relates to image data, carry out
an OPT and check the recorded images.
710
CAPSULE
Record-data too big
The amount of data received by the VDR exceeds the capacity of
the fixed capsule. This is typically caused by receipt of too much
image data. Use the “Analysis of recorded data” utility on the BCP
or in the configurator tool to determine the cause. If the problem
relates to image data, carry out an OPT and check the recorded
images.
721
FLOAT-FREE
Not recording
The VDR is unable to record data to the float-free capsule. Another
error explaining why (e.g. #722 FLOAT-FREE Cannot find) is
normally displayed in advance. Try to fix the preceding error,
otherwise reboot the system.
722
FLOAT-FREE
Cannot find
The VDR is unable to detect the float-free capsule. Check that the
float-free capsule is connected correctly. If the error persists, the
float-free capsule is probably defective.
723
FLOAT-FREE
Cannot access
The VDR has detected a float-free capsule but is unable to get
access to the memory. If the error persists, the float-free capsule is