Instruction CF-RD Room Thermostat with Display
7VI.UH.Q4.1C Produced by Danfoss Floor Heating Hydronics 03.2007
GB
Press the up/down selector to set the mini-
mum room temperature limitation
Press the push button
shortly, the actual
room temperature is shown in the display
4. Transmission Test
Initiate transmission test on Room Thermostat
- g. 1
Press the push button
LED goes ON
Link test is satisfactory
LED
goes OFF
Link test is unsatisfactory
LED
ashes 5 times
No Link connection to Room Thermostat
Try to relocate Room Thermostat in the room
Or install Repeater Unit (CF-RU) and locate be
-
tween Master Controller and Room Thermostat
Note: Master Controller output LED(s) connected to the
room thermostat, ash(es) during Link test