Operating Guide
VLT® AutomationDrive FC 302
90-710 kW, D9h-D10h and E5h-E6h Enclosed Drives
drives.danfoss.com

Table of Contents

Questions and Answers

  • P
    pbautistaSep 8, 2025
    How to fix AMA check Unom and Inom error on Danfoss DC Drives?
    • R
      robertthomasSep 8, 2025
      If you encounter issues with AMA check Unom and Inom on your Danfoss DC Drives, it means the settings for motor voltage, motor current, and motor power are wrong. Check the settings in parameters 1-20 to 1-25.
  • M
    Marcia HaynesSep 8, 2025
    How to resolve AMA low Inom error on Danfoss D9h?
    • S
      Stephanie PerkinsSep 8, 2025
      If you encounter AMA low Inom on your Danfoss DC Drives, it means the motor current is too low. Check the settings.
  • C
    Crystal ReillySep 9, 2025
    Why am I getting a temperature input error on my Danfoss DC Drives?
    • D
      David Jackson IVSep 9, 2025
      If your Danfoss DC Drives displays a temperature input error, the temperature sensor is not connected.
  • W
    whiteandreaSep 9, 2025
    What to do if 24 V supply is low on Danfoss DC Drives?
    • S
      Stacy TuckerSep 9, 2025
      If the 24 V supply is low in your Danfoss DC Drives, which is measured on the control card, check for a defective control card.
  • J
    Julie DavidsonSep 9, 2025
    How to fix '10 Volts low' error on Danfoss D9h?
    • D
      Daniel ColeSep 9, 2025
      If your Danfoss DC Drives shows '10 Volts low', it could be due to a short circuit in a connected potentiometer or improper wiring. Remove the wiring from terminal 50. If the warning clears, the problem is with the wiring. If the warning doesn't clear, replace the control card.
  • S
    Stephanie MillerSep 9, 2025
    What does '1.8 V supply low' mean on Danfoss D9h DC Drives?
    • M
      Michelle ArmstrongSep 9, 2025
      If the 1.8 V DC supply is low on your Danfoss DC Drives, it indicates that the 1.8 V DC supply used on the control card is outside of allowable limits. Check for a defective control card.
  • R
    Robert DunnSep 10, 2025
    What to do if brake check failed on Danfoss D9h DC Drives?
    • Z
      zdavilaSep 10, 2025
      If the brake check failed on your Danfoss DC Drives, it means the brake resistor is not connected or not working. Check 2-15 Brake Check.
  • C
    christine53Sep 10, 2025
    What to do if option module configuration has changed on Danfoss D9h DC Drives?
    • J
      Julie RobertsSep 10, 2025
      If the option module configuration has changed in your Danfoss DC Drives, verify that the configuration change was intentional and then reset the unit.
  • C
    Cynthia BowenSep 12, 2025
    What does illegal FC configuration mean for Danfoss D9h?
    • M
      Michael SchmittSep 12, 2025
      If your Danfoss DC Drives displays an illegal FC configuration, it means the control card and power card are incompatible. Contact the Danfoss supplier.
  • A
    Aaron GrahamSep 12, 2025
    What causes DC overvoltage in Danfoss DC Drives and how to fix it?
    • C
      colemanjosephSep 12, 2025
      If your Danfoss DC Drives display a DC overvoltage error, it indicates that the DC-link voltage exceeds the limit. Here are some potential solutions: * Connect a brake resistor. * Extend the ramp time. * Change the ramp type. * Activate the functions in parameter 2-10 Brake Function. * Increase parameter 14-26 Trip Delay at Inverter Fault. If the alarm/warning occurs during a power sag, consider using kinetic back-up (parameter 14-10 Mains Failure).

Danfoss D9h Specifications