Danfoss ECL Comfort 300 - Set Room and DHW Temperature

Danfoss ECL Comfort 300
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The yellow
side of the
ECL Card
Go to display C.
Circuit I:
Setting the desired room temperature
02
Desired room
temp. in comfort
mode
61
Desired room
temp. in setback
mode
Select the constant comfort mode.
Set the desired room temperature for the comfort
mode.
Select the constant setback mode.
Set the desired room temperature for the setback
mode.
Select the desired mode (section 2).
The setting of the desired room temperature is important even if
a room temperature sensor / room panel / remote control is not
connected.
Is the room temperature too low?
Make sure that the radiator thermostats do not limit the room
temperature.
If you still cannot obtain the desired room temperature by
adjusting the radiator thermostats, the ow temperature is too
low. Increase the desired room temperature.
Circuit II:
Setting the desired DHW temperature
55
Desired DHW
temp. in comfort
mode
01
Desired DHW
temp. in setback
mode
Select the constant comfort mode.
Set the desired DHW temperature for the comfort
mode.
Select the constant setback mode.
Set the desired DHW temperature for the setback
mode.
Select the desired mode (section 2).
3
Set your room and DHW
temperature