Customer ports
Size 060 080 110 160 210 250
Axial and radial
1)
DN19 typ 1 DN25 typ 1 DN25 typ 1 DN32 typ 1 DN32 typ 1 DN32 typ 1
Case drain ports
2)
0.875 [
7
∕
8
]–14UN-2B 1.0625 [1
1
∕
16
]–12UN-2B 1.313 [1
5
∕
16
]–12UN-2B]
Axial gauge
ports
2)3)
0.875 [
7
∕
8
]–14UN-2B
1.0625 [1
1
∕
16
]–12UN-2B
Radial gauge
port
2)3)
0.5625 [
9
∕
16
]–18UNF-2B
1)
Split flange Boss per ISO6162, 40 MPa series
2)
SAE O-ring boss
3)
Countersink may be deeper that specified in the standard.
Operating Parameters
Output Speed
Output Speed Displacement Unit
Size
060 080 110 160 210 250
Rated
Maximum 32°
min
-1
(rpm)
3600 3200 2900 2600 2350 2200
Minimum 6° 5900 5300 4800 4250 3850 3650
Zero 0° 6600 5950 5350 4750 4300 4050
Maximum
Maximum 32° 4500 4100 3700 3300 3000 2800
Minimum 6° 7250 6600 5950 5250 4800 4500
Zero 0° 7950 7200 6500 5750 5250 4900
System and Case Pressure, Ambient Temperature
Parameter All sizes
System pressure Maximum working 450 bar [6527 psi]
Maximum 480 bar [6962 psi]
Minimum
1) 2)
Case pressure Rated 3 bar [44 psi]
Maximum 5 bar [73 psi]
Minimum 0.3 bar [4 psi]
Ambient temperature
3)
Maximum 70 °C [158 °F]
Minimum -40 °C [-40 °F]
1)
Minimum above case pressure (open and closed circuit)
2)
See the graphs Required inlet pressure diagrams (for cylinder block filling) on page 16.
3)
Air temperature close to the unit.
Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
Technical specifications
14 |
©
Danfoss | August 2018 AX00000025en-US0504